3-2. ADJUSTMENT REQUIREMENTS LIST

Adjustment Item
Touch Panel Adj.
Orig. Size Adjust
Address Adjust
ATDC Sensor Adjust
AIDC Sensor Adjust
Universal Tray width detection
adjustment
Zoom (FD) Adjust
Registration (CD)
Registration (FD)
Lead Edge Erase
Trail Edge Erase
Loop Adjustment
γ Table
Erasure Width
Zoom (CD)
Zoom (FD)
Scale (CD)
Scale (FD)
Requirements
Automatically adjusted
410 ± 0.5 mm
5.0 ± 0.5 mm
3.0 ± 1.0 mm
Approx. 3.0 mm
Within reference grada-
tion range
3.0 mm
200 ± 1.0 mm
300 ± 1.5 mm
0 ± 0.5 mm
D-68
Adjustment Point
Control Panel
Control Panel
Ref. page
D-82
D-83
D-84
D-85
D-86
D-87
D-90
D-91
D-92
D-94
D-96
D-98
D-100
D-102
D-104
D-106
D-108
D-110