9) Zoom (FD) Adjust

Requirement
NOTE
This adjustment must be made when the PH or the Scanner Drive Cable has been replaced.
Adjustment Procedure
1. Call the Adjust mode to the screen.
2. Touch [Printer] and [Zoom (FD) Adjust], in that order.
3. Select the Universal Tray for the paper source and load A3 in the tray.
4. Press the Start key to let the copier produce a test pattern.
5. Check to see if width A on the test pattern is up to the specifications. If it is outside the specified
range, perform the following adjustment steps.
6. Use the 10-key Pad to change the setting value.
Setting Instructions
If width A is longer than the specifications, make the setting value smaller than the current one.
If width A is shorter than the specifications, make the setting value greater than the current one.
1) Use the following equation to find the setting value:
[Specification (410 mm) - measurement] / 0.5 = setting value
2) If a single adjustment procedure does not successfully bring width A into the specified range, try
another setting value.
7. Touch the [Enter] key to validate the setting value.
Caution
Be sure to touch the Enter key before returning to the normal operation mode. If the Panel Reset
Key is used, the previous setting remains valid.
Width A on the test pattern output should fall within the
following range.
Specification
410 ± 0.5 mm
1155D208AA
1155D205CA
D-90
Adjust Mode
Zoom (FD) Adjust
3
4
5
6
7
8
9
0
C
Use to clear the setting value.
Use to enter the setting value.
Setting Range
-3 to +3
Use to chage the + or - sign.
1155D189CA