12) Lead Edge Erase

Requirement
NOTE
This adjustment must be made after the PH has been replaced and following Registration (CD, FD)
and Zoom (FD) Adjust.
Adjustment Procedure
1. Call the Tech. Rep. mode to the screen.
2. Touch [Tech. Rep. Choice] and [Printer], in that order.
3. Touch [Lead Edge Erase].
4. Press the Start key to let the copier produce a test pattern. Then, press the Stop key.
5. Check to see if width A on the test pattern is up to the specifications. If it is outside the specified
range, perform the following adjustment steps.
6. Use the 10-key Pad to change the setting value.
Setting Instructions
If width A is longer than the specifications, make the setting value smaller than the current one.
If width A is shorter than the specifications, make the setting value greater than the current one.
• If a single adjustment procedure does not successfully bring width A into the specified range, try
another setting value.
7. Touch the [Enter] key to validate the setting value.
Caution
Be sure to touch the Enter key before returning to the normal operation mode. If the Panel Reset
Key is used, the previous setting remains valid.
8. Call the Tech. Rep. mode to the screen.
9. Touch [Function] and [Printer Function], in that order.
10. Touch [F12] test pattern output.
11. Select 600 dpi for DPI, F12-3 for the test pattern, and 1st Drawer for the paper source.
Width A on the test pattern output should fall within the
following range.
Note: The measurement shall be taken at the center on the
leading edge of the paper.
Specification
3.0 ± 3.0 mm
1155D156AB
1155D198CA
D-94
Adjust Mode
Lead Edge Erase
3
4
5
6
7
8
9
0
C
Use to clear the setting value.
Use to enter the setting value.
Setting Range
0 to 5
1155D190CA
1155D190CA