1155SBS050406A
6) I.R. & EDH Check
This function allows the Tech. Rep. to make the various functional tests and adjustments, choice set-
tings, and sensor checks as they relate to the IR and EDH.
Touch Panel Display
I.R. & EDH Check
Function (IR)
Address Adjust
Exp. Lamp Check
Focus Check
Zoom (CD)
Zoom (FD)/Scale
Scale (CD)
Tech. Rep. Mode
Makes the various functional tests and adjustments, choice settings, and
sensor checks as they relate to the IR and EDH.
Performs the following functions.
Adjusts the address at which to monitor the intensity of light.
<Procedure>
1. Press the Start key to start the measurement cycle.
2. If the measurement result is okay, touch [Save] (which highlights the
key) to save the measurement.
Note 1: The copier automatically stops as soon as it completes the mea-
surement cycle. The Stop key may, however, be pressed to halt
the sequence.
Note 2: Be sure to run this function when the CCD Unit or a Scanner part
(including the Exposure Lamp) has been replaced with a new one.
Checks to see whether the Exposure Lamp turns ON properly and for the
maximum and minimum values of the intensity of lamp light.
Note: The Touch Panel shows "OK" if the intensity data and light distribu-
tion ratio fall within the specified range, and "NG" if they fall outside
the range. It gives the message of "Unable" if the check sequence is
abnormally terminated.
<Procedure>
Press the Start key to start the measurement cycle.
Note: The copier automatically stops as soon as it completes the measure-
ment cycle. The Stop key may, however, be pressed to halt the
sequence.
Automatically checks the focus level of the IR and shows the results of the
check.
Note: This function is only for factory setting and should never be used in
the field.
Adjusts the zoom ratio in the CD (main scanning) direction and shows the
results.
Note: This function is only for factory setting and should never be used in
the field.
Automatically adjusts the zoom ratio in the FD (sub-scanning) direction
and the Original Length Scale position and shows the results.
Note: This function is only for factory setting and should never be used in
the field.
Automatically adjusts the Original Width Scale position in the CD (main
scanning) direction and shows the results.
Note: This function is only for factory setting and should never be used in
the field.
S-40