Scsi-2 Fast Transfers 10.0 Mbytes (8-Bit Transfers) Or 20.0 Mbytes (16-Bit Transfers) 40 Mhz Clock; Ultra Scsi Transfers 20.0 Mbytes (8-Bit Transfers) Or 40.0 Mbytes (16-Bit Transfers) Quadrupled 40 Mhz Clock - LSI LSI53C875A Technical Manual

Pci to ultra scsi controller
Table of Contents

Advertisement

Table 6.42
SCSI-2 Fast Transfers 10.0 Mbytes (8-Bit Transfers) or 20.0 Mbytes
(16-Bit Transfers) 40 MHz Clock
Symbol
Parameter
t
Send SREQ/ or SACK/ assertion pulse width
1
t
Send SREQ/ or SACK/ deassertion pulse width
2
t
Receive SREQ/ or SACK/ assertion pulse width
1
t
Receive SREQ/ or SACK/ deassertion pulse width
2
t
Send data setup to SREQ/ or SACK/ asserted
3
t
Send data hold from SREQ/ or SACK/ asserted
4
t
Receive data setup to SREQ/ or SACK/ asserted
5
t
Receive data hold from SREQ/ or SACK/ asserted
6
Table 6.43
Ultra SCSI Transfers 20.0 Mbytes (8-Bit Transfers) or
40.0 Mbytes (16-Bit Transfers) Quadrupled 40 MHz Clock
Symbol
Parameter
t
Send SREQ/ or SACK/ assertion pulse width
1
t
Send SREQ/ or SACK/ deassertion pulse width
2
t
Receive SREQ/ or SACK/ assertion pulse width
1
t
Receive SREQ/ or SACK/ deassertion pulse width
2
t
Send data setup to SREQ/ or SACK/ asserted
3
t
Send data hold from SREQ/ or SACK/ asserted
4
t
Receive data setup to SREQ/ or SACK/ asserted
5
t
Receive data hold from SREQ/ or SACK/ asserted
6
1. Transfer period bits (bits [6:4] in the
Clock Cycle of Data Setup bit (bit 7 in
2. During Ultra SCSI transfers, the value of the Extend REQ/ACK Filtering bit
(STEST2), bit 1) has no effect.
6-56
SCSI Transfer (SXFER)
SCSI Control One
Electrical Specifications
Min
30
30
22
22
24
34
14
24
1, 2
Min
15
15
11
11
12
17
6
11
register) are set to zero and the Extra
(SCNTL1)) is set.
(SCSI Test Two
Max
Unit
ns
ns
ns
ns
ns
ns
ns
ns
Max
Unit
ns
ns
ns
ns
ns
ns
ns
ns

Advertisement

Table of Contents
loading

Table of Contents