Disclaimer It is the policy of LSI Corporation to improve products as new technology, components, software, and firmware become available. LSI reserves the right to make changes to any products herein at any time without notice.
User Guide and the CLI Guide, combined as one resource. It is only available on your 3ware CD, in the /doc/3wareHTMLBookshelf folder. Online help is also available when you are using 3DM2™ (3ware Disk Manager 2). LSI 3ware 9750 SATA+SAS RAID Controller Card Installation Guide...
Chapter 1. Getting Started The LSI 3ware 9750 SATA+SAS RAID controller card provides these features: Support for up to 127 SAS and/or SATA devices per controller, single port only. Release 10.2 adds external support. ® ® ® OS support includes FreeBSD...
Chapter 1. Getting Started Contents of this Package If you purchased a full retail kit with cables, the following items are included: One of the 3ware 9750 RAID controller card models in Table 1. Table 1: 9750 Controller Card Family Model Ports...
Page 7
1 x SFF8088 Four internal 4x lane SATA+SAS cables with sideband support. One external 4x lane SATA+SAS cable. 9750-24i4e 6 x SFF8087 1 x SFF8088 Six internal 4x lane SATA+SAS cable with sideband support, one external 4x lane SATA+SAS cable. www.lsi.com/channel/products...
Chapter 1. Getting Started 9750 Controller Card Models Figure 1. Layout of the 4-Port 3ware 9750-4i SATA+SAS RAID Controller Card System Error Heat Sink for J4L1 on back RAID-On-Chip (ROC) CRT6A1 Ports Port 0 JT3B1 JT5B3 JT6B1 JT6B3 85049-09 JT5B2...
Page 9
9750 Controller Card Models Figure 3. Layout of the 8-Port 3ware 9750-4i4e SATA+SAS RAID Controller Card J6A2 J6A1 J6A3 85062-01 J1A4 J1A1 J2B2 Port J1A2 J1A3 J6B1 J1A5 Port J1B1 J2B1 J6B2 CR3B2 System Error (Red LED) CR3B1 Drive Activity (Green LED)
Important: You should only use LSI 3ware certified cables with your LSI 3ware RAID controller. Using an incorrect cable can result in drives that are not detected. The appropriate cables are included with your controller. If you must replace a...
Drive Requirements The 3ware RAID controller is designed for use with drive capacities beyond 2 TB. SAS and/or SATA drives can be used with the 3ware 9750 RAID controller. SATA drives must meet SATA-2 (3.0 Gbps) or SATA-3 (6.0 Gbps) standards and also be included on the list of supported drives on the interoperability list.
System Requirements For a list of supported drives, access the LSI website at http://www.lsi.com/channel/support/marketing_resources. Click the Data & Interoperability tab. Operating System Requirements 3ware 9750 RAID controller may be used with the following operating systems for Intel and AMD 32-bit and 64-bit x86 based...
The 3ware 9750 RAID controller card should be installed by technically qualified persons. If you are uncomfortable opening a computer system and conforming to standard ESD (electrostatic discharge) practices, you should have a computer technician perform the installation.
Protecting Equipment and Data Heat Sink Warning. Do not replace the factory-installed heat sink shipped with the 3ware 9750 SATA+SAS controller cards. Replacing the heat sink alters the thermal characteristics and cooling requirements and may cause the controller to fail. Replacing the factory-installed heat sink voids the warranty.
Air Flow, Cable Length, and Routing Space Adequate airflow and ventilation are particularly important for 3ware 9750 RAID controller card. The on-board heat sink collects heat, and must have adequate airflow in order to disburse it. It is important that the cables do not obstruct the air flow or prevent proper ventilation of the system.
Page 17
PC users some low-cost motherboards have a single PCI Note: Express slot which is reserved for a video card. These slots cannot accommodate a 3ware 9750 SATA+SAS controller card or other PCI-E device. If there is an extra open PCI Express x8 or x16 slot in your computer, install the controller card next to it to provide additional ventilation for the controller.
An ESD grounding strap or mat A Phillips screwdriver Before You Start 3ware 9750 SATA+SAS controller cards can be installed in a standard enclosure or in an enclosure with a backplane. Be sure to read “Safety Information” on page 10 in Chapter 1.
To connect your BBU directly or remotely to your 3ware 9750 RAID controller card see: “Installing the iBBU07 Directly on the Your 3ware 9750 Controller Card” “Connecting the iBBU07 Remotely to the 3ware 9750 Controller Card” Installing the iBBU07 Directly on the Your 3ware 9750...
Page 20
RAID controller. Install the RAID controller in a PCI Express slot in the computer. Connecting the iBBU07 Remotely to the 3ware 9750 Controller Card Use the supplied 20-pin cable to connect the iBBU07 to your RAID controller.
11.) Open the computer case according to the manufacturer’s instructions. Locate the PCI Express slot you want to use for the 3ware 9750 SATA+SAS controller card. For a discussion of which slot to use, see “Selecting the Slot in Which to Install the Controller Card”...
Page 22
Check that the 3ware SATA+SAS controller’s metal bracket covers the hole in the case and secure the bracket with the screw that was used to secure the filler bracket in step 5. LSI 3ware 9750 SATA+SAS RAID Controller Card Installation Guide...
SFF 8088 cables. Follow these steps to connect the cable from your controller to a drive enclosure. Connect the connector on one end of the cable to the external port, as shown in Figure 11. www.lsi.com/channel/products...
Page 24
Connect the other end of the cable to the external port on the drive enclosure. Figure 11. Mini SAS x4 Cable Plug Connector and the RAID Controller Card with External Connector Note: Figure 11 for reference only, . LSI 3ware 9750 SATA+SAS RAID Controller Card Installation Guide...
Connecting the Controller to the Backplane Figure 12. Backplane 8087 Multi-lane Cable SFF-8087 JT3B1 Connector 85049-10 Chassis PCI-e Slot Motherboard Note: Figure 12 is for reference only. System connection may not be the same as shown in this illustration. www.lsi.com/channel/products...
Version 10.0 or newer for information about configuring RAID arrays. The user guide is included on the 3ware CD that came with your controller. It is also available from the LSI website at: http://www.lsi.com/channel/ChannelDownloads. LSI 3ware 9750 SATA+SAS RAID Controller Card Installation Guide...
9750-4i4e, and 9750-8e Controller Cards PCI Edge Connector State 1 State 2 State 3 3.3 V supply 0.330 A 0.330 A 0.330 A 12 V supply 1.000 A 1.810 A 1.530 A 3.3 V auxiliary supply 0.030 A 0.030 A 0.030 A www.lsi.com/channel/products...
1.139 A 1.174 A 1.225 A 1.356 A 12 V supply 1.466 A 1.426 A 1.487 A 1.773 A 3.3 V auxiliary supply 0.048 A 0.026 A 0.214 A 0.168 A LSI 3ware 9750 SATA+SAS RAID Controller Card Installation Guide...
33 G, 11 ms half-sine, 10± shocks in 3± shocks in x-, y-, and z-axes x-, y-, and z-axes Airflow At least 200 linear feet per minute (LFPM) Caution! Do not operate the 9750 Controller Card at any time without proper cooling. www.lsi.com/channel/products...
1. The Self Monitoring Analysis and Reporting Technology (SMART) detects up to 70 percent of all predictable drive failures. In addition, SMART monitors the internal performance of all motors, heads, and drive electronics. LSI 3ware 9750 SATA+SAS RAID Controller Card Installation Guide...
The RAID controller interfaces with the host system using this connector. JT3B1 Battery 20-pin connector backup unit (BBU) Connects the optional intelligent battery connector backup unit (LSI iBBU07) directly to the controller. J4L1 Remote 20-pin connector. battery backup unit Connects the optional remote intelligent (BBU)
Page 32
Jumper should not be present during normal operation. JT6B2 Reserved for 2-pin connector LSI use only JT6B3 Drive activity 2-pin connector connector Connects to an external LED that indicates drive activity. LSI 3ware 9750 SATA+SAS RAID Controller Card Installation Guide...
Page 33
Table 8: Jumpers and Connectors for 9750-4i4e Jumper/ Type Description Connector J1A1 UART debug 4-pin connector. connector Reserved for LSI use. J1A2 Reserved for 2-pin connector. LSI use Jumper should not be present during normal operation. J1A3 Reserved for 2-pin connector.
Page 34
J6B1 Remote 20-pin connector. battery backup Connects the optional remote intelligent unit (BBU) battery backup unit (LSI iBBU07) connector remotely to the controller by cable. LSI 3ware 9750 SATA+SAS RAID Controller Card Installation Guide...
Page 35
Jumper and Connector Description for the 9750 Controller Card Family Table 8: Jumpers and Connectors for 9750-4i4e (continued) Jumper/ Type Description Connector J6B2 Battery 20-pin connector. backup unit Connects the optional intelligent battery connector backup unit (LSI iBBU07) directly to the controller. www.lsi.com/channel/products...
Page 36
SATA drives, or a SAS expander. J2B1 Standard x8 PCIe 2.0 bus connection as defined in PCIe edge the PCI Express specification. card connector The RAID controller interfaces with the host system using this connector. LSI 3ware 9750 SATA+SAS RAID Controller Card Installation Guide...
Page 37
Connects the optional remote intelligent unit (BBU) battery backup unit (LSI iBBU07) connector remotely to the controller by cable. J6B2 Battery 20-pin connector. backup unit Connects the optional intelligent battery connector backup unit (LSI iBBU07) directly to the controller. www.lsi.com/channel/products...
Page 38
Connects the controller by cable to SAS drives or SATA drives, or a SAS expander. J1B3 RAID key 2-pin connector. connector Enables support for RAID 5 configurations. Jumper should not be present during normal operation. LSI 3ware 9750 SATA+SAS RAID Controller Card Installation Guide...
Page 39
LSI use. Reserved for LSI use. J1L1 Remote 20-pin connector. battery backup Connects the optional remote intelligent unit battery backup unit (LSI iBBU07) connector remotely to the controller by cable. J2B1 4 Lane SFF-8087 x4 internal mini SAS SATA+SAS connector connector...
Page 40
SAS expander. J4B2 4 Lane SFF-8087 x4 internal mini SAS SATA+SAS connector connector (Ports 0-3) Connects the controller by cable to SAS drives or SATA drives, or a SAS expander. LSI 3ware 9750 SATA+SAS RAID Controller Card Installation Guide...
Page 41
Connects to an LED that indicates when the data in the cache has yet to be written to the storage devices. Used when the write-back feature is enabled. J5B3 UART debug 4-pin connector connector Reserved for LSI use. www.lsi.com/channel/products...
Page 42
Connects the controller by cable to SAS drives or SATA drives, or a SAS expander. J1B3 RAID key 2-pin connector. connector Enables support for RAID 5 configurations. Jumper should not be present during normal operation. LSI 3ware 9750 SATA+SAS RAID Controller Card Installation Guide...
Page 43
Reserved for LSI use. J1L1 Remote 20-pin connector. battery backup Connects the optional remote intelligent unit (BBU) battery backup unit (LSI iBBU07) connector remotely to the controller by cable. J2B1 4 Lane SFF-8088 x4 external mini SAS SATA+SAS connector. connector...
Page 44
SATA drives, or a SAS expander. J5A1 4 Lane SFF-8087 x4 internal mini SAS SATA+SAS connector. connector (Ports 4-7) Connects the controller by cable to SAS drives or SATA drives, or a SAS expander. LSI 3ware 9750 SATA+SAS RAID Controller Card Installation Guide...
Page 45
SAS expander. J5B2 4 Lane SFF-8087 x4 internal mini SAS SATA+SAS connector. connector (Ports 0-3) Connects the controller by cable to SAS drives or SATA drives, or a SAS expander. J5B3 UART debug 4-pin connector connector Reserved for LSI use. www.lsi.com/channel/products...
Red LED The ROC ASIC is operating normally. Indicates the LSI SAS Indicates a hardware error during 2108 RAID-on-chip POST or a CPU exception during (ROC) ASIC error status operation. LSI 3ware 9750 SATA+SAS RAID Controller Card Installation Guide...
C-Tick mark FCC Self-Certification logo Canadian Compliance Statement Korean MIC Taiwan BSMI Japan VCCI CISPR Class B All 3ware 9750 RAID controller card hardware is compliant with CSA C22.2 No.60950-1, UL 60950-1 First Edition-listed accessory, Agency model # 25239. www.lsi.com/channel/products...
For specific answers to questions, technical support, or to give feedback about the product, refer to our website at: http://www.lsi.com/channel/ContactUS. LSI also offers support 24 hours a day, 7days a week at: 888-646-4566 or 408-433-4567 in North America. For international customers call 00-800-5745-6442.
Need help?
Do you have a question about the 3ware 9750 and is the answer not in the manual?