Set Single Cable RS-232 STX Character

This feature selects the STX character.
To specify the STX Character:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code,
cover any unused bar codes on this and the facing page to ensure the scanner reads only
the bar code you intend to scan.
3. Scan the appropriate characters/digits from the
the decimal designation for the desired character. A table containing the ASCII Character
Set and their corresponding decimal values is available in the inside back cover of this
manual. ASCII parameters must be input by scanning decimal digits for each character.
Pad all numbers with leading zeroes to yield a three-digit entry (001-127). Thus, to set a
single character value of A, bar codes containing the digits '0', '6' and '5' must be scanned.
The selectable range for this option is any decimal value from 001 to 127.
4. The scanner will automatically exit Programming Mode when the appropriate amount of
digits have been scanned.
DEFAULT