EAS Security Level

This feature defines the level of EAS security for operating in coupled mode.
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan your selection from the bar codes below. You'll need to cover any unused bar codes
on this and the facing page to ensure that the scanner reads only the bar code you intend
to scan.
3. Complete the programming sequence by scanning the Enter/Exit Programming Mode bar
code.
058901(CR)
EAS Security Level = Medium
DEFAULT
Product Reference Guide
Enter/Exit Programming Mode
058900(CR)
EAS Security Level = Low
058902(CR)
EAS Security Level = High