Standard 2 of 5 Check Character Calculation
Enables/disables calculation and verification of an optional Standard 2 of 5 check character.
To set this feature:
1. Scan the ENTER/EXIT Programming Mode bar code.
2. Scan either the enable or disable barcode below. You'll need to cover any unused barcodes
on this and the facing page to ensure that the scanner reads only the barcode you intend to
scan.
3. Complete the programming sequence by scanning the ENTER/EXIT Programming
Mode bar code.
DEFAULT
049601(CR)
Standard 2 of 5 Check Character Calculation = Enable
Product Reference Guide
If check character calculation is disabled, the risk is increased that a
misread can occur. When disabled, any check character in a barcode is
treated as data character.
NOTE
Enter/Exit Programming Mode
049600(CR)
Standard 2 of 5 Check Character Calculation = Disable
363