Auxiliary Port Mode

Selects the usage for the scanner's optional auxiliary port. The choices listed below are mutually
exclusive (only one option can be active at a time).
Disabled — Port is inactive
External Handheld Input — Supports Datalogic
1000, QuickScan
HotShot. Call your dealer for more information about supported devices.
PIR/CT plus Diagnostics Reporting — PIR (Productivity Index Reporting) allows the
scanner to provide information to an external computer indicating how easy the label was
to read. CT (Cashier Training) allows the scanner to provide feedback to the cashier on
how to scan in a more ergonomic fashion.
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan your selection from the bar codes below. You'll need to cover any unused bar codes
on this and the facing page to ensure that the scanner reads only the bar code you intend
to scan.
3. Complete the programming sequence by scanning the Enter/Exit Programming Mode bar
code.
DEFAULT
050901(CR)
Auxiliary Port Mode = External Handheld Input
Product Reference Guide
TM
6000, PowerScan
Cable pinout information for the Aux Port is provided in
this manual. A connected handheld scanner must be configured to transmit
data as outlined in
NOTE
Enter/Exit Programming Mode
TM
handheld scanners (QuickScan
TM
) as well as other models such as the Symbol®
Appendix
D.
050900(CR)
Auxiliary Port Mode = Disable
050902(CR)
Auxiliary Port Mode = PIR/CT + Diagnostics Reporting