1D Double Read Timeout
The 1D Double Read Timeout feature specifies the minimum allowable time which must pass
before reading the same 1D label again (e.g. two identical items in succession).
To set the Double Read Timeout:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan your selection from the bar codes below. You'll need to cover any unused bar codes
on this and the facing page to ensure that the scanner reads only the bar code you intend
to scan.
3. Complete the programming sequence by scanning the Enter/Exit Programming Mode bar
code.
DEFAULT
004D3C(CR)
1D Double Read Timeout = 600ms
004D64(CR)
1D Double Read Timeout = 1 Second
Product Reference Guide
General Scanner and Scale Features
If the incidence of multiple reads is not acceptable, increase the Double
Read Timeout setting to a higher value.
NOTE
Enter/Exit Programming Mode
Chapter 9
004D28(CR)
1D Double Read Timeout = 400ms
004D50(CR)
1D Double Read Timeout = 800ms