Shift Test (6 Pounds Dual Interval ONLY)
The Shift Test checks to ensure that items placed anywhere on the weighing surface of the
scanner/scale are weighed properly. Refer to
Figure 52. Shift Test
Product Reference Guide
Figure 52
when performing this test.
1. Place and remove, in succession, a six-pound load
on the center of each of the four quadrants: 1, 2,
3, and 4, (as shown in
scale's weigh platter. Verify that a reading of
between 5.995 and 6.005 lb. registers, under load,
in each quadrant tested. Check that the display
returns to 0.00 between each load.
2. After verifying the accuracy of each quadrant of
the weighing surface, remove all weight from the
scale. This completes the 6 pound Shift Test.
(Models vary)
DUAL INTERVAL
Figure
52) of the scanner/
2
1
4
3
79