Environmental Specifications
TABLE:
Specification
Ambient temperature
(Does not apply to
removable media)
Relative humidity
Altitude
Acoustic noise
Vibration
Shock
Set conditions to the optimal temperature and humidity ranges to minimize the
chance of downtime due to component failure. Operating the Sun Server X4-2 for
extended periods at or near the operating range limits, or installing it in an
environment when it remains at or near nonoperating range limits could significantly
increase hardware component failure. See also:
"Temperature Guidelines" on page 12
■
"Humidity Guidelines" on page 12
■
Operating
• Maximum range: 41˚F to 95˚F (5˚C to 35˚C) up to
2,953 feet (900 meters)
• Optimal: 69.8˚F to 73.4˚F (21˚C to 23˚C)
Note - Maximum ambient operating temperature
is derated by 1 degree C per 300 meters of
elevation beyond 900 meters, up to a maximum
altitude of 3,000 meters.
• 10% to 90% noncondensing, short term 25˚F to
113˚F (–5˚C to 55˚C)
• 5% to 90% noncondensing, but not to exceed
0.024 kg of water per kg of dry air (0.053 lbs
water/2.205 lbs dry air)
Up to 9,840 feet (3,000 meters)
Note - In China markets, regulations may limit
installations to a maximum altitude of 6,562 feet
(2,000 meters).
• Maximum condition: 7.91 Bels A weighted
• Idle condition: 5.28 Bels A weighted
0.15 G (z-axis),
0.10 G (x-, y-axes), 5-500Hz swept sine
IEC 60068-2-6 Test FC
3 Gs, 11 ms half-sine
IEC 60068-2-27 Test Ea
Nonoperating
–40˚F to 158˚F (–40˚C to 70˚C)
Up to 93% noncondensing
100.4˚ (37.7˚C) maximum wet
bulb
Maximum 39,370 feet (12,000
meters)
Not applicable
0.5 G (z-axis),
0.25 G (x-, y-axes), 5-500Hz
swept sine
IEC 60068-2-6 Test FC
Roll-off:
1-inch roll-off free fall, front to
back rolling directions
Threshold:
25 mm threshold height at 0.75
m/s impact velocity
ETE-1010-02 Rev A
Preparing for Server Installation
11
Need help?
Do you have a question about the Server X4-2 and is the answer not in the manual?
Questions and answers