Sun Microsystems Fire X4170 Manual

Sun Microsystems Fire X4170 Manual

Hide thumbs Also See for Fire X4170:

Advertisement

Sun

Integrated Lights Out Manager

(ILOM) 2.0 Supplement for Sun Fire
X4170, X4270, and X4275 Servers
Sun Microsystems, Inc.
www.sun.com
Part No. 820-7629-10
March 2009, Revision A
Submit comments about this document at: http://www.sun.com/hwdocs/feedback

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fire X4170 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sun Microsystems Fire X4170

  • Page 1: Integrated Lights Out Manager

    Integrated Lights Out Manager ™ (ILOM) 2.0 Supplement for Sun Fire ™ X4170, X4270, and X4275 Servers Sun Microsystems, Inc. www.sun.com Part No. 820-7629-10 March 2009, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback...
  • Page 2 Etats-Unis et dans d’autres pays et licenciée exclusivement par X/Open Company, Ltd. Sun, Sun Microsystems, le logo Sun, Java, Sun Studio, Solaris et Sun Fire sont des marques, ou des marques déposée de Sun Microsystems, Inc., ou ses filiales, aux Etats-Unis et autres pays.
  • Page 3: Table Of Contents

    Supported Platform Firmware 2 Supported ILOM 2.0 Feature Set 3 Platform-Specific Features 3 ILOM Platform Features for the Sun Fire X4170, X4270, and X4275 Servers 5 Resetting the Root Password to the Factory Default 6 ILOM Sideband Management 6 ▼...
  • Page 4 Power Supply Fault Sensors 20 Fan and Security Sensors 21 Power Supply Unit Current, Voltage, and Power Sensors 22 Entity Presence Sensors 22 Index 25 Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers • March 2009...
  • Page 5: Preface

    Preface The Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers contains information about ILOM 2.0 that is specific to the Sun Fire X4170, X4172, and X4275 Servers. For a complete discussion of ILOM 2.0 firmware and its capabilities, along with user procedures, see the Sun Integrated Lights Out Manager 2.0 User’s Guide (820-1188).
  • Page 6 Sun Integrated Lights Out ILOM features and tasks that 820-1188 Manager 2.0 User’s Guide are common to servers and HTML server modules that support ILOM Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers • March 2009...
  • Page 7 Part Number Format Sun Integrated Lights Out ILOM information that is 820-7629 Manager Supplement for Sun specific to the Sun Fire X4170, HTML Fire X4170, X4270, and X4275 X4270, and X4275 Servers Servers Sun Fire X4170, X4270, and Hardware safety and...
  • Page 8: Typographic Conventions

    Please include the title and part number of your document with your feedback: Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers, part number 820-7629-10. viii Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers • March 2009...
  • Page 9: Ilom 2.0 Feature Sets

    C H A P T E R ILOM 2.0 Feature Sets This chapter provides a brief overview about ILOM, as well as defines the purpose of ILOM’s common and platform features offered in ILOM 2.0. The following topics are discussed in this chapter: “ILOM Overview”...
  • Page 10: Ilom Overview

    Supported Platform Firmware TABLE 1-1 ILOM SP Version Host BIOS Version Applicable Hardware 2.0.3.9 07.01.38.03 Sun Fire X4170, X4270, and X4275 Servers Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers • March 2009...
  • Page 11: Supported Ilom 2.0 Feature Set

    Supported ILOM 2.0 Feature Set The Sun Fire X4170, X4270, and X4275 Servers support the entire ILOM feature set provided in ILOM 2.0. In addition, the servers supports platform-specific features offered in ILOM as of ILOM 2.0.3.9. For information about the use of the ILOM 2.0 feature set, see the Sun Integrated Lights Out Manager 2.0 User’s Guide (820-1188) and the Addendum to the Sun Integrated...
  • Page 12 Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers • March 2009...
  • Page 13: Ilom Platform Features For The Sun Fire X4170, X4270, And X4275 Servers

    Sun Fire X4170, X4270, and X4275 Servers This chapter provides platform-specific information related to ILOM 2.0 running on the Sun Fire X4170, X4270, and X4275 Servers. The following topics are covered in this supplement: “Resetting the Root Password to the Factory Default” on page 6 ■...
  • Page 14: Resetting The Root Password To The Factory Default

    You can configure sideband management using either the web interface, the command-line interface (CLI), the BIOS, or IPMI. For instructions, see the following sections: Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers • March 2009...
  • Page 15: Configure Sideband Management Using The Web Interface

    The Network Settings page appears. 3. In the Network Settings page, do the following: a. Select DHCP to acquire the IP address automatically or specify the appropriate IP address. Chapter 2 ILOM Platform Features for the Sun Fire X4170, X4270, and X4275 Servers...
  • Page 16: Configure Sideband Management Using The Cli

    For instructions, see “Use the Serial Connection to Change the ILOM SP IP Address” in the Sun Fire X4170, X4270, and X4275 Servers Installation Guide (820- 5827) Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers • March 2009...
  • Page 17 4. To set the SP management port to a sideband port, type the following commands: -> set /SP/network pendingmanagementport=/SYS/MB/NETn Where n equals 0, 1, 2, or 3. -> set commitpending=true Chapter 2 ILOM Platform Features for the Sun Fire X4170, X4270, and X4275 Servers...
  • Page 18: Configure Sideband Management Using The Host Bios Setup Utility

    To configure sideband management using the host BIOS Setup utility, perform the following steps: 1. Power on or power cycle the server. Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers • March 2009...
  • Page 19 (POST). When BIOS is started, the main BIOS Setup utility top-level screen appears. This screen provides seven menu options across the top of the screen. Chapter 2 ILOM Platform Features for the Sun Fire X4170, X4270, and X4275 Servers...
  • Page 20 3. In the main screen, select Advanced → IPMI Configuration. The IPMI Configuration screen appears. Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers • March 2009...
  • Page 21 (NET0, NET1, NET2, NET3). The NET MGT port is the default. c. Select Commit for the change to take effect. Chapter 2 ILOM Platform Features for the Sun Fire X4170, X4270, and X4275 Servers...
  • Page 22: Switch Serial Port Output Between Sp And Host Console

    To switch the serial port output using the ILOM web interface, perform the following steps: 1. Log in to the ILOM web interface. Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers • March 2009...
  • Page 23: Switch Serial Port Output Using The Cli

    By default, Service Processor is selected. 4. Click Save for your change to take effect. ▼ Switch Serial Port Output Using the CLI 1. Log in to the ILOM CLI. Chapter 2 ILOM Platform Features for the Sun Fire X4170, X4270, and X4275 Servers...
  • Page 24: Clear Server Faults

    PCIe faults can cover one or more of the following components: /SYS/MB/NETn ■ and /SYS/MB/RISERn/PCIEn. The procedure for clearing a fault differs depending on the type of fault: Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers • March 2009...
  • Page 25: Server Chassis Intrusion Sensors

    If proper service actions are taken, you should not see either the /SYS/INTSW or /SYS/SP/SP_NEEDS_REBOOT sensors asserted unless there are other issues, such as a misaligned chassis intrusion switch. Chapter 2 ILOM Platform Features for the Sun Fire X4170, X4270, and X4275 Servers...
  • Page 26: How The /Sys/Sp/Sp_Needs_Reboot Sensor Works

    /SYS/INTSW and /SYS/SP/SP_NEEDS_REBOOT sensors will be asserted and the SP will operate in a degraded mode. Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers • March 2009...
  • Page 27: Sensors Reference Information

    LEDs and powering off the server. This section describes the sensors that ILOM monitors for the Sun Fire X4170, X4270, and X4275 Servers.
  • Page 28: Temperature Sensors

    Power supply n current fault /SYS/PSn/VOLT_FAULT Fault Power supply n voltage fault /SYS/PSn/FAN_FAULT Fault Power supply n fan fault /SYS/PSn/TEMP_FAULT Fault Power supply n temperature fault Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers • March 2009...
  • Page 29: Fan And Security Sensors

    To clear this fault, replace the server’s top cover, power down the server’s host, and reboot the server’s SP. For more information, see “Server Chassis Intrusion Sensors” on page Chapter 2 ILOM Platform Features for the Sun Fire X4170, X4270, and X4275 Servers...
  • Page 30: Power Supply Unit Current, Voltage, And Power Sensors

    Fan board n; Fan module n present monitor /SYS/FBn/PRSNT Entity presence Fan board present monitor /SYS/MB/Pn/PRSNT Entity presence Motherboard; CPUn present monitor Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers • March 2009...
  • Page 31 /SYS/MB/Pn/Dn/PRSNT Entity presence Motherboard; CPUn; Memory DIMM n present monitor /SYS/MB/RISERn/PRSNT Entity presence PCIe riser n present monitor /SYS/MB/RISERn/PCIen/PRSNT Entity presence PCIe card n present monitor Chapter 2 ILOM Platform Features for the Sun Fire X4170, X4270, and X4275 Servers...
  • Page 32 Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers • March 2009...
  • Page 33: Index

    Index BIOS related documents, v firmware versions supported, 2 root password setting, 6 chassis intrusion sensor benefits, 17 sensors how it works, 17 entity presence, 22 chassis intrusion switch fan, 21 how tripped, 17 power, 22 power supply, 20 security, 21 temperature, 20 documentation serial port...
  • Page 34 18 Sun support, vii training where to find, vii UNIX commands, vii web sites third party, viii Sun Integrated Lights Out Manager 2.0 Supplement for Sun Fire X4170, X4270, and X4275 Servers • March 2009...

This manual is also suitable for:

Fire x4270Fire x4275

Table of Contents