1 Process of the Initial Configuration
Step 3 Configuring the IP address of the AS based on the network environment.
----End

1.5 Setting Up the Management Environment

Introduce how to set up the management environment of S5600.
Prerequisite
For the iSCSI networking:
l
l
Procedure
Step 1 Connect the ASs, switches and maintenance terminal.
Step 2 Check that grounding cables are fixed to the cabinet after cables are connected.
Table 1-2

Table 1-2 Cable connection checklist

Item
Grounding
cable
1-8
NOTE
When installing the driver of the FC HBA, you need to choose the driver based on the FC HBA compatibility
list. After obtaining the information about the storage devices, OS, and system patch, you can determine
the driver version based on the FC HBA compatibility list.
CAUTION
The IP addresses of the two iSCSI host ports on the same controller must be configured in
different subnets. In addition, none of the IP addresses can be in the same network segment
as the IP address of the management network port.
The IP addresses of iSCSI host ports on the controller must be configured in a different
network segment from the IP address (192.168.2.0/24) of the controller heartbeat network
port. Otherwise, an IP conflict occurs in the network and services fail to run properly.
NOTE
For details on the networking of the S5600, see
describes the cable connection checklist.
Normal
The grounding cables of the
l
controller subrack, disk subracks,
and switches are connected to the
grounding terminals of the cabinet.
The ASs and maintenance
l
terminals are properly grounded as
required.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
OceanStor S5600 Storage System
Initial Configuration Guide
"2 Setting Up the Management
Abnormal
The grounding cables of the
l
controller subrack, disk subracks,
or switches are not connected to
the grounding terminal of the
cabinet, or the connections are
loosened.
The ASs or maintenance
l
terminals are not properly
grounded.
Environment".
Issue 02 (2009-09-30)