1 Process of the Initial Configuration
Item
Network
cable
Serial cable
a: It is used when the S5600 and ASs form the FC SAN with FC switches.
b: It is used when the S5600 and ASs form the FC SAN with the direct connection.
c: For details on how to install the small form-factor pluggable (SFP) module and optical
fibers, see the OceanStor S5600 Controller Subrack User Guide.
d: It is used when the S5600 configured with FC and iSCSI host ports and ASs form the IP
SAN with Ethernet switches.
During power-on, do not insert or remove hard disks, controllers, expander modules, or optical
fibers and optical modules. Otherwise, data might be lost.
Step 3 Power on the cabinet, D200 disk subracks, S5600 controller subrack, switches, and ASs in turn.
----End
1.6 Configuring the IP Address of the Management
Network Port on the Controller
Introduce how to configure the IP address of the management network port on the S5600
controller.
1-10
Normal
The network cables connect the
l
network port of the AS to the
Ethernet switch and connect the
iSCSI host port on the controller to
the Ethernet switch
The network cable connects the
l
management network port on a
controller to the network port on
the maintenance terminal.
NOTE
For details on how to connect the network
cables when setting up the cluster
environment, see the related product
documents.
The serial port on a controller is
connected to the RS-232 serial port on
the maintenance terminal by a serial
cable (with an RJ-45 connector at one
end and a DB-9 connector at the other
end).
CAUTION
NOTE
When setting up the cluster environment, you need to set the power-on parameters of each device. For
details on the power-on sequence of the cluster, see the related product documents.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
OceanStor S5600 Storage System
Abnormal
The network cables do not
l
connect the network port of the
AS to the Ethernet switch or
connect the iSCSI host port on the
controller to the Ethernet switch.
d
.
The network cable does not
l
connect the management network
port on a controller to the network
port on the maintenance terminal.
The COM serial port on either
controller is not connected to the
RS-232 serial port on the
maintenance terminal.
Initial Configuration Guide