Connectivity Fault Management
C
ONFIGURING
CFM M
AINTENANCE
A
SSOCIATIONS
To configure detailed settings for maintenance domains:
Click Administration, CFM.
1.
Select Configure MD from the Step list.
2.
Select Configure Details from the Action list.
3.
Select an entry from the MD Index.
4.
Specify the MEP archive hold and MEP fault notification parameters.
5.
Click Apply
6.
Figure 297: Configuring Detailed Settings for Maintenance Domains
Use the Administration > CFM (Configure MA) pages to create and
configure the Maintenance Associations (MA) which define a unique CFM
service instance. Each MA can be identified by its parent MD, the MD's
maintenance level, the VLAN assigned to the MA, and the set of
maintenance end points (MEPs) assigned to it.
CLI R
EFERENCES
"CFM Commands" on page 1311
C
U
OMMAND
SAGE
Creating a Maintenance Association
Use the Configure MA – Add screen to create an MA within the selected
MD, map it to a customer service instance (S-VLAN), and set the
manner in which MIPs are created for this service instance. Then use
the MEP List to assign domain service access points (DSAPs) to this
service instance (see
page
529).
An MA must be defined before any associated DSAPs or remote MEPs
can be assigned (see
page
530).
– 524 –
"Configuring Maintenance End Points" on
"Configuring Remote Maintenance End Points" on