Edge-Core ECS3510-28T Management Manual page 188

Edge-core 28/52-port fast ethernet layer 2 switch
Table of Contents

Advertisement

| Interface Configuration
C
5
HAPTER
Saving Power
Power savings can only be implemented on Gigabit Ethernet ports
N
:
OTE
when using twisted-pair cabling. Power-savings mode on a active link only
works when connection speed is 1 Gbps, and line length is less than 60
meters.
P
ARAMETERS
These parameters are displayed:
Port – Power saving mode only applies to the Gigabit Ethernet ports
using copper media.
Power Saving Status – Adjusts the power provided to ports based on
the length of the cable used to connect to other devices. Only sufficient
power is used to maintain connection requirements. (Default: Enabled
on Gigabit Ethernet RJ-45 ports)
W
I
EB
NTERFACE
To enable power savings:
Click Interface, Green Ethernet.
1.
Mark the Enabled check box for a port.
2.
Click Apply.
3.
Figure 60: Enabling Power Savings
– 188 –

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecs3510-52t

Table of Contents