Configuring Telnet Settings - Edge-Core ECS3510-28T Management Manual

Edge-core 28/52-port fast ethernet layer 2 switch
Table of Contents

Advertisement

C
T
ONFIGURING
ELNET
S
ETTINGS
Use the System > Telnet menu to configure parameters for accessing the
CLI over a Telnet connection. You can access the onboard configuration
program over the network using Telnet (i.e., a virtual terminal).
Management access via Telnet can be enabled/disabled and other
parameters set, including the TCP port number, time outs, and a password.
Note that the password is only configurable through the CLI.) These
parameters can be configured via the web or CLI interface.
CLI R
EFERENCES
"Line" on page 728
"Telnet Server" on page 828
P
ARAMETERS
The following parameters are displayed:
Telnet Status – Enables or disables Telnet access to the switch.
(Default: Enabled)
TCP Port – Sets the TCP port number for Telnet on the switch.
(Default: 23)
Max Sessions – Sets the maximum number of Telnet sessions that can
simultaneously connect to this system. (Range: 0-8; Default: 8)
A maximum of eight sessions can be concurrently opened for Telnet and
Secure Shell (i.e., both Telnet and SSH share a maximum number or
eight sessions).
Login Timeout – Sets the interval that the system waits for a user to
log into the CLI. If a login attempt is not detected within the timeout
interval, the connection is terminated for the session.
(Range: 10-300 seconds; Default: 300 seconds)
Exec Timeout – Sets the interval that the system waits until user input
is detected. If user input is not detected within the timeout interval, the
current session is terminated. (Range: 60-65535 seconds;
Default: 600 seconds)
Password Threshold – Sets the password intrusion threshold, which
limits the number of failed logon attempts. When the logon attempt
threshold is reached, the system interface becomes silent for a
specified amount of time (set by the Silent Time parameter) before
allowing the next logon attempt. (Range: 1-120; Default: 3 attempts)
Silent Time – Sets the amount of time the management interface is
inaccessible after the number of unsuccessful logon attempts has been
exceeded. (Range: 1-65535 seconds; Default: Disabled)
Password checking can be enabled or disabled for login to the
N
: