Edge-Core ECS3510-28T Management Manual page 985

Edge-core 28/52-port fast ethernet layer 2 switch
Table of Contents

Advertisement

Trap messages enabled by the
to any management station configured by the
command.
E
XAMPLE
The following example sets alarm thresholds for the signal power received
at port 1.
Console(config)interface ethernet 1/25
Console(config-if)#transceiver-threshold rx-power low-alarm -21
Console(config-if)#transceiver-threshold rx-power high-alarm -3
Console#
This command sets thresholds for the transceiver temperature which can
transceiver-
be used to trigger an alarm or warning message.
threshold
temperature
S
YNTAX
transceiver-threshold temperature {high-alarm | high-warning
| low-alarm | low-warning} threshold-value
high-alarm – Sets the high temperature threshold for an alarm
message.
high-warning – Sets the high temperature threshold for a warning
message.
low-alarm – Sets the low temperature threshold for an alarm
message.
low-warning – Sets the low temperature threshold for a warning
message.
threshold-value – The threshold of the transceiver temperature.
(Range: -12800 - 12800 in units of 0.01 Celsius)
D
EFAULT
High Alarm: 75.00
HIgh Warning: 70.00
Low Alarm: -123.00
Low Warning: 0.00
C
OMMAND
Interface Configuration (Ethernet)
C
OMMAND
Refer to the Command Usage section under the
current
thresholds.
Trap messages enabled by the
to any management station configured by the
command.
S
ETTING
°
C
°
C
°
C
°
C
M
ODE
U
SAGE
command for more information on configuring transceiver
– 985 –
| Interface Commands
C
26
HAPTER
Transceiver Threshold Configuration
transceiver-monitor
command are sent
snmp-server host
transceiver-threshold
transceiver-monitor
command are sent
snmp-server host

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecs3510-52t

Table of Contents