Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
The access to the Engineer programming menus is from one keyboard only while all other connected to the system
bus keyboards are temporally disabled for any operation. The LCD keyboards display a message „Engineer Mode!!!"
The default programming style is the one using text tree-structure for the engineer menus. To change the programming
style at the beginning you have to enter first the engineer menu with valid code (7777 by default) and choose in
sequence:
7777 – 2.SETTINGS – 14. MENU STYLE: TEXT, ADDRESS or OPERATION
Confirm your final choice with ENTER.
At every exit from the engineer programming menu the system updates all changes of parameters and settings. The
update will take some time depending on the system structure, volume and number of parameters' changes.
Before starting the programming of any system parameter read carefully the provided detailed information for
each menu and make sure that you understand the descriptions.

6.1 Organization of the Engineer Programming Menus

For Installer's convenience, every programming parameter description includes the access via all the programming
types:
Important Notes!

6.2 Indication

The indication while programming different system parameter is performed in several common types according the
structure of the address or operation.
- Indication for introducing time values
LCD
LED 16/
LED 32
LED 8/
LED 16A
- Indication for introducing parameter "ENABLE/ DISABLE" type
LCD
LED 16/
LED 32
ADDRESS
ENG1 CODE
OPERATION
TEXT MENU
Programming
Menu type
Parameter
Enter the new time using the digit buttons. The time interval varies according
the parameter. For values smaller than 10 enter "00" in front of it – for example
005.
The zones 14, 15 and 16 show the number of the digits of the parameter. The
zones from 1 to 10 show the current set value for every digit, as 10 means 0.
The currently set digit is blinking. Use the arrows to review the values set to all
digits. For example, the zone 14 is blinking – the first digit of the parameter
and its value is 0 (10 lighting on). Move to the right to review the set value for
the second digit – zone 15 is blinking and 1 is lighting on. Enter the new time
using the digit buttons. Every pressing of a button sets new value and
automatically moves the cursor to the right.
The zones 1, 2 and 3 show the number of the digits of the parameter. LED
symbol "V" is lighting on to show that the system is in value programing mode.
Lighting on digit button shows the current set value for every digit.
"DISABLE" or "ENABLE" is displayed on the screen. Press random digit button
or arrows to switch over.
The "ENABLE" parameter is set when the zone numbers from 1 to 8 are
lighting on; The "DISABLE" parameter is set when all zone numbers are off.
Press random digit button or arrows to switch over.
0000
000
3. CODES – 2. ENGINEER – 1. ENG1 CODE
Access
18