ADDRESS
A ACCOUNT
OPERATION
LENGTH
TEXT MENU
Setting the area account number digit length
An account number digit length is assigned at this address. The digit length can be 4 or 6-digit.
Every pressing of a random button or arrows changed alternatively the parameter.
At this address for you set the parameter as:
4 digits
6 digits
When switching from 4- to 6-digits account numbers, the digits 00 will automatically be added at the
end. For example, the 4-digits number 1234 will become 123400.
When changing over from 6- to 4-digits numbers, only the first four figures in the 4-digits
number will remain valid. For example, the 6-digits number 123456 will become 1234. Due to
risk of coincidence of account numbers, changing over from 6- to 4-digits numbers IS NOT
RECOMMENDED!
Default setting: 4 digits
ADDRESS
A DOUBLE
OPERATION
KNOCK
TEXT MENU
Setting the "Double knock" delay time for zones
The engineer assigns a time interval from 1 to 5-minute at this address. The time interval starts
running when a detector in the zone is activated for the first time when the system is armed. An
alarm event is registered if second detector activation is recorded within this interval in the same or
another zone.
An alarm event will also be registered if no zone is restored within 15 seconds of the first activation
of the zone.
Default setting: 3 minutes
ADDRESS
ARM ON NO
OPERATION
MOVE
TEXT MENU
Setting a time for automatic arming of the area on no moving activity in the zones
The Engineer sets a time for automatic arming of the area when there is no moving activity in all
associated to that area zones. The time is common for all areas in the system. The automated
arming is enabled on the respective area address 4xx5 (option 5), where "xx" is the area number
from 1 to 8.
Enter a time from 001 to 255 minutes. The set 000 value disables the automatic arming of the area.
Pay attention that the automatic arming will start if there is a set time at the address and after all
zones in the respective area are closed. Check also the set options at address 4xx5 (option 5 is
enabled) for the respective area.
Default setting: [000]
4000
400
6. PARTITIONS – 1. ACCOUNT LENGTH
The area account number is 4-digit.
The area account number is 6-digit.
4001
401
6. PARTITIONS – 2. DOUBLE KNOCK
4002
402
6. PARTITIONS – 3. NO MOV ALARM
Eclipse 8/ 16/ 32 Series - Engineer Programming Manual