Teletek electronics CA62 Installation And Programming Manual
Teletek electronics CA62 Installation And Programming Manual

Teletek electronics CA62 Installation And Programming Manual

Advertisement

Quick Links

Alarm Control Panel
CA62
Installation and Programming
Manual
WARNING
This manual contains information on limitations regarding product use and function and information
on the limitations as to liability of the manufacturer. The entire manual should be carefully read.
The information in this manual is a subject to change without notice!
C

Advertisement

Table of Contents
loading

Summary of Contents for Teletek electronics CA62

  • Page 1 Alarm Control Panel CA62 Installation and Programming Manual WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. The information in this manual is a subject to change without notice!
  • Page 2 Guarantee During the guarantee period the manufacturer shall, at its sole discretion, replace or repair any defective product when it is returned to the factory. All parts replaced and/or repaired shall be covered for the remainder of the original guarantee, or for ninety (90) days, whichever period is longer.
  • Page 3: Table Of Contents

    2.11 Installing of VD60 voice dialer to CA62 Alarm Control Panel ..............15 2.12 Installing of AJAX LAN Module in CA62 Alarm Control Panel ............... 16 2.13 Connecting of UWE432 Universal Wireless Expander to CA62 Alarm Control Panel ......16 2.14 Powering up the CA62 Alarm Control Panel ..................17 2.14.1 Technical Trouble Indication .....................
  • Page 4: Section 1: Installation

    The system is based on a modular principle. The programming of CA62 can be done by two types of keyboards (LED or LCD) or remotely via ProSTE software. The security control is managed by means of a keyboard or a proxi reader.
  • Page 5: Installation

    ➢ Avoid any loops of connecting wires within the very box and in their passage over or under the printed- circuit boarding. ➢ Additional relays MUSt Not be placed in the CA62 Alarm control panel box as these may generate electromagnetic interference when switched.
  • Page 6: Са62 Alarm Control Panel Metal Box

    Installation and Programming Manual - СА62 Alarm Control Panel 2.3 СА62 Alarm Control Panel Metal Box Figure 1. Situation of СА62 alarm panel in metal box. Figure 2. Side view and mounting of universal metal box.
  • Page 7: Ca62 Alarm Control Panel Plastic Box

    Installation and Programming Manual - СА62 Alarm Control Panel 2.4 СА62 Alarm Control Panel Plastic Box Figure 3. Opening the CA62 plastic box and template for wall mounting. 1 - Central support opening (behind PCB) 5 - Main cable opening...
  • Page 8: Ca62 Alarm Control Panel Inputs And Outputs

    Installation and Programming Manual - СА62 Alarm Control Panel 2.5 CA62 Alarm Control Panel Inputs and outputs CA62 Figure 5. CA62 control panel inputs and outputs. Terminals description of СА62 control panel: • AC - Power supply from 17V / 17VA mains transformer ...
  • Page 9: Connecting Of Detectors To Ca62 Alarm Control Panel

    Use the supplied 1 kΩ resistors to balance the zones. The balancing resistors are installed on the last detector of the circuit. The zones, which shall not be used, are terminated with one 1 kΩ resistor at the terminals of the CA62 Control Panel, irrespective of the chosen type of zone balancing.
  • Page 10 1 Fire Reset and the active status must be +12 VDC. c) Connecting of two fire detectors to a doubling zone. Figure 7. Connecting of key-switch and a fire detector to CA62 alarm control panel.
  • Page 11: Connecting Of Peripheral Devices To Са62 Alarm Control Panel

    Installation and Programming Manual - СА62 Alarm Control Panel 2.7 Connecting of Peripheral Devices to СА62 Alarm Control Panel 2.7.1 Connecting LED and LCD Keyboards to CA62 Alarm Control Panel Two types of keyboards can be used to control and program the СА62 alarm panel: •...
  • Page 12 Jt jumper should be placed on the most distant one. the Jt jumper is set by default. The cable connecting the LED60 and the LED61 Keyboards to the CA62 Control Panel must be no longer than 250m and have a cross-section of no less than 0.25mm.
  • Page 13: Connecting Of Proxi Reader Pr62 To Ca62 Alarm Control Panel

    PR62 any attractive supplement to the security system. The PR62 can be connected to the terminals RED, GREEN, YELLOW and BLACK of the CA62 together with the mounted keyboards. Up to four proximity readers can be included within one security system. Programming the various addresses onto the readers will provide identification by the TAMPER of each of these.
  • Page 14: Using Of Pgm1, Pgm2 And Pgm3 Programmable Outputs

    Installation and Programming Manual - СА62 Alarm Control Panel Using of PGM1, PGM2 and PGM3 Programmable outputs The СА62 Alarm panel PGM1, PGM2 and PGM3 outputs have a programmable active level. This allows them to be used to transmit control signals towards external devices (e.g. a block siren input) or to directly control low-powered external devices (e.g.
  • Page 15: Connecting The Ca62 Built-In Digital Communicator

    - by zone or by event (see description of ADDRESS 6035). Turn off the power supply in order to connect the PCB of the voice telephone dialer to the EXPAND socket of the CA62 Control Panel (1). Fix the PCB onto the pre-mounted plastic spacers (2). The telephone line should be connected to terminals A and B of the СА62 Control Panel.
  • Page 16: Installing Of Ajax Lan Module In Ca62 Alarm Control Panel

    2.12 Installing of AJAX LAN Module in CA62 Alarm Control Panel AJAX Module is an additional accessory for built-in installation in CA62 any other security or fire control system. It transmits the system status to Monitoring centre or to the User via Internet. The AJAX module enables easy monitoring and transmitting of alarm events occurring in the security system to existing Monitoring centre using standard monitor- ing software.
  • Page 17: Powering Up The Ca62 Alarm Control Panel

    Follow the next installation procedure when power-up the CA62 system for the first time: ➢ Set the JPRG jumper (Figure 5) on CA62 control panel, in order to configure the control panel default pa- rameters (the factory settings).
  • Page 18: Section 2: Programming

    - Lights off Keyboard programming Entering the system engineer code will initiate the CA62 Alarm System programming mode for the engineer param- eters. After restoring the default parameters (system RESET) the engineer code will remain 7777. When you enter the engineer programming menu the indication of the used keyboards will be as follows: - LeD Keyboards - the LEDs RDY (green), ARM (red), TRBL (yellow) and BPS (red) are blinking together.
  • Page 19: Remote Programming Of Ca62

    Detailed working instructions for the ProSTE software program are provided in the built-in Help files. The connection between the local computer and the CA62 control panel is via a specialized module (the module is not included in the CA62 equipment and is sold as a separate product.) The details listed in this manual apply to all parameters for remote system programming.
  • Page 20: Engineer Parameters And Common Settings

    Installation and Programming Manual - СА62 Alarm Control Panel 0. eNGINeeR PARAMeteRS AND CoMMoN SettINGS ADDReSS 0000 - CHANGING tHe eNGINeeR CoDe A new access code to the alarm station engineer parameters can be assigned at this address. Note: If the 6-digit long access code is set, the combination "00" automatically will be added at the end of all valid codes in the system.