General Information For Operation With Led16 And Led32 - Teletek electronics ECLIPSE 16 Engineer Programming Manual

Alarm control panels
Table of Contents

Advertisement

Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
- The reviewed ADDRESS number is 0097 – Changing the programming style type.
- To go back to the parameter settings mode press the
- Manager Programming
To access the manager programming menus enter valid manager code (0000 by default). A confirmation sound signal
will be heard. Press the PRG (
and
are lighting on. The manager programming menus are 2-digit and are described in details in ECLIPSE
Series Operation Manual – Manager and User Programming. If 30 sec after entering the manager programming there
is no activity (pressed button), the system will exit in normal operation mode. It is possible to enter in manager
programming menus from several keyboards at a time using the same manager access code.
Example for date setting in Manager programming menus using LED8/ 16A keyboard:
- Enter valid Manager code (0000 by default) and press
- LEDs
and
of 2-digit ADDRESS number.
- Enter 15 – ADDRESS for date setting.
- LEDs
and
button is lighting on (the set date by default is 01/01/12).
- Enter the new date using the format DDMMYY. You can use the buttons with arrows to review the entered
new date before saving it – the lighting on digit button shows the set value for every currently blinking zone number on
the display.
- Confirm the new set date with ENTER.

2.6. General Information for Operation with LED16 and LED32

LED 16 and LED 32 are keyboards with LED display, suitable for management and programming of ECLIPSE Series
control panels. LED 16 has indication for 16 zones and can control 2/3 independent areas. LED 32 has indication for
32 zones and can control 8 independent areas.
The keyboards LED 16(A) and LED 32 operate with limited functionality when connected to ECLIPSE 8 control panel –
operation with one area (A in LED16) and 8 zones. LED 32 operate with limited functionality when connected to
ECLIPSE 16 control panel – operation with three areas (A, B and C) and 16 zones.
- Engineer Programming
The engineer programming menus are accessible only when the system is disarmed.
According to the set programming style after entering an engineer code (7777 by default) the LED displays:
-
The zone numbers 13, 14, 15 and 16 lighting on - 4-digit ADDRESS programming style
The zone numbers 14, 15 and 16 lighting on -3-digit OPERATION programming style операции
-
The both LEDs „lightning" (white) and „padlock" (red) are blinking together showing that the system is in engineer
programming mode. Now, the system waits for entering of ADDRESS or OPERATION for programming – by default
the 4-digit ADDRESS programming style is set.
Use the digit buttons to enter an ADDRESS number – the detailed description of the ADDRESSES and their
functionality is provided in item 7. Every pressing of a button enters one digit and the lighting on zone numbers are
reduced with one, the number of the pressed digit button lights up (for 0 lights on digit 10). According the entered
address number the indication for the parameters is different. Use the address descriptions provided in item 7 to
orientate for the required settings. To confirm the entered settings press the ENTER button, to reject them – the
CANCEL button. To return to the display for address entering press single the CANCEL button. To exit the engineer
programming menu press the CANCEL button once again. The keyboard is in normal operation mode when LEDs
"Lightning" (white) and "padlock" (green) are lighting on together with the numbers of the used areas.
Attention: The exit of engineer programming menu is not automatic! To exit the engineer menu press CANCEL button
several times until return to the normal operation mode.
) button to enter in manager programming menus. Zone numbers 1 and 2, and LEDs
are lighting on. Zone number 1 is blinking, and 2 is lighting on – the system waits for entering
are lighting on. Zone number 1 is blinking, zones from 2 to 6 are lighting on. The "0" digit
button again.
button.
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eclipse 8Eclipse 32

Table of Contents