Teletek electronics ECLIPSE 16 Engineer Programming Manual page 63

Alarm control panels
Table of Contents

Advertisement

ADDRESS
T1
OPERATION
OPTIONS
TEXT MENU
Setting of holidays for operation on Timeslot 1
The engineer sets at this address those holidays included in the Timeslot 1 operation. When this
option is enabled (1 is selected) for Timeslot 1, the system will also notes the settings at addresses
5411 – 5524, where the engineer sets the holidays and officially nonworking days for every month in
the year.
Default setting: none
The addresses of Time slots from 2 to 8 are programmed in an analogical way.
The settings of holidays and officially nonworking days are programmed at individual addresses, as for every month
four separate addresses are provided. The holidays and nonworking days are common for all Timeslot numbers. All
months are programmed analogically on different addresses – see the quick reference table at the beginning of this
section.
JAN 1-8
ADDRESS
JAN 9-16
OPERATION
JAN 17-24
TEXT MENU
JAN 35-31
Setting of holidays and nonworking days for January
The address 5411 presents 8 different fields for the first eight days of January. Every field is editable
when the cursor is under it. The cursor can be moved with the arrows. In the square parentheses on
the right side of the screen, the engineer can see the editable date. To set a date as holiday move
the cursor under it and press button "0". The selected holidays for the month are presented with "H"
capital letter. Pressing the button "0" once again will return the previous status.
Indication:
LCD: The workdays are displayed with "-" symbol. The holidays are displayed with "Н" symbol.
LED: The zone numbers corresponding to the days set for holidays are lighting on.
In the text menu structure the holidays and nonworking days are set after entry in 01. JANUARY
submenu. The holidays are selected with pressing button "1" – see also the description for operation
with text structure in item 1. GENERAL INFORMATION and APPENDIX 5.
The other days of January are set on the following address in an analogical way.
5411>T JAN 1-8
[--------] [01]
0
Default setting: none
5013
513 + 01
7. SCHEDULES – 1. TIMESLOTS – 1. TIMESLOT – 4.OPTIONS
5411; 5412; 5413; 5414
541 + 01; 542 + 01; 543 + 01; 544 + 01
7. SCHEDULES – 2. CALENDAR – 01. JANUARY
_
Define Holidays
[H-------] [01]
_
The cursor is under the first day.
The JAN 1st is set as holiday.
Days from 1 to 8
Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
5411>T JAN 1-8
[H-------] [02]
_
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eclipse 8Eclipse 32

Table of Contents