Teletek electronics ECLIPSE 16 Engineer Programming Manual page 30

Alarm control panels
Table of Contents

Advertisement

Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
ADDRESS
U1 OPTIONS
OPERATION
TEXT MENU
User 01 Operation rights
User code 01 is the Chief Manager in the system and always has full rights for operation and
programming of the system, which cannot be changed or erased!
The following options are available for User Code 01:
1. DISARM ENABLE
2. PART ARM ENABLE
Partial arming
3. BYPASS ENABLE
Zone Bypassing
4. PROGRAM ENABLE
5. N.A
6. N.A
7. N.A
8. MANAGER ENABLE
MANAGER in the
system
Default settings: All rights are enabled
ADDRESS
U1 AREAS
OPERATION
TEXT MENU
Association of Areas to User 01
The engineer associates areas to User code 01 at this address. The User can operate (arm, disarm,
bypass zones) only with area numbers associated to its code. One or several areas can be
associated to the user code. To select area, press the corresponding to its number digit button. Next
pressing of the same button will deselect the same area. The final configuration is confirmed with
ENTER button.
The User code 01 is always associated to at least one area number. All other user codes will
be inactive if there are no associated areas to them, irrespective of the assigned rights at the
previous!
It is possible the associated area numbers to the control device (keyboard or card reader) to be
different according to the area numbers associated to User code 01. In this case, the user code or
proximity card can operate only in the common areas for the device and the code. For example, if to
the user code all areas are associated in the system, and the associated to the control device areas
are 1, 2, 3 and 4, then and the user code can operate only with them.
To associate all areas to the user press button "0" – the button alternatively switches over all
enabled / all disabled state.
Default setting: All Areas
1010
110+01
3. CODES – 1. USERS – 01. USER – 1. OPTIONS
The user has the right to disarm the system.
The user has the right to perform partial arming of the system – STAY
or SLEEP Arming type.
The user has the right to perform zone bypassing in system.
The user has the right to change its own access code, to review the
memory LOG file, to bypass zones and other options.
The user code is Manager in the system – it has the right to change
other user access codes and to access the Manager's programming
menus.
1011
111+01
3. CODES – 1. USERS – 01. USER – 2. AREAS