Teletek electronics ECLIPSE 16 Engineer Programming Manual page 44

Alarm control panels
Table of Contents

Advertisement

Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
ADDRESS
Z1 LINE
OPERATION
TEXT MENU
Checking the line resistance
The engineer can check the line resistance of the zone at this address. It is suitable to perform
diagnostics of the zone troubles. The displayed value can vary according the used hardware
connection style in the system and has the following meaning:
Connection style
See also APPENDIX 6.
The ZONES with numbers from 02 to 08 for ECLIPSE 8, from 02 to 16 for ECLIPSE 16 and from 02 to 32 for ECLIPSE
32 are programmed in an analogical way.
2019
219 + 01
4. INPUTS – 5. ZONES – 01. ZONE – 9. LINE RESIST
Displayed value
< 1.5 kΩ
1
> 1.5 kΩ
< 0.75 kΩ
0.75 – 1.5 kΩ
2
> 1.5 kΩ
< 0.75 kΩ
0.75 – 1.5 kΩ
3
> 1.5 kΩ
< 0.75 kΩ
0.75 – 5.6 kΩ
4
> 5.6 kΩ
< 0.75 kΩ
0.75 – 1.5 kΩ
5
1.5 - 5.6 kΩ
> 5.6 kΩ
< 0.5 kΩ
0.5 – 1.5 kΩ
6
1.5 – 2.7 kΩ
2.7 kΩ - ∞
< 0.5 kΩ
0.5 – 1.5 kΩ
1.5 – 2.7 kΩ
7
2.7 – 4.9 kΩ
> 4.9 kΩ
< 0.75 kΩ
0.75 – 1.5 kΩ
1.5 – 2.5 kΩ
8
2.5 – 3.7 kΩ
3.7 – 4.9 kΩ
> 4.9 kΩ
< 0.5 kΩ
0.5 - 0.75 kΩ
0.75 - 1.5 kΩ
9
1.5 – 2.7 kΩ
> 2.7 kΩ
The zone is closed.
The zone is open.
The zone is open.
The zone is closed.
The zone is open.
The zone is open.
The zone is closed.
The zone is open.
The zone is closed.
The zone is open.
Tamper break down.
Tamper short-circuit.
The zone is closed.
The zone is open.
Tamper break down.
The both zones are closed.
st
The 1
zone is open, the 2
st
The 1
zone is closed, the 2
The both zones are open.
The both zones are closed.
st
The 1
zone is open, the 2
st
The 1
zone is closed, the 2
The both zones are open.
Tamper break down.
Tamper short-circuit.
The both zones are closed.
st
The 1
zone is open, the 2
st
The 1
zone is closed, the 2
The both zones are open.
Tamper break down.
Tamper short-circuit.
The both zones are closed.
st
The 1
zone is closed, the 2
st
The 1
zone is open, the 2
The both zones are open.
44
Description
nd
zone is closed.
nd
zone is open.
nd
zone is closed.
nd
zone is open.
nd
zone is closed.
nd
zone is open.
nd
zone is open.
nd
zone is closed.