Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
ADDRESS
PGM 01
OPERATION
DEACT. TM
TEXT MENU
Deactivation timer for PGM 01 – setting a time for deactivation the event programmed at
address 3013
A deactivation timer for the programmed at ADDRESS 3013 event is set at this address. The state
of PGM 01 will restore after the set time is over. The engineer enters time in range 000 – 255 as the
time unit (seconds or minutes) depends on the settings at ADDRESS 3011, option 5. By default, the
programmed time unit is in seconds.
Default setting: [000]
ADDRESS
PGM 01
OPERATION
DELAY
TEXT MENU
Time delay for activation of PGM 01
A time delay for the programmed at ADDRESS 3013 event is set at this address. The activation of
PGM 01 will be delayed in time. The engineer enters time in range 000 – 255 as the time unit
(seconds or minutes) depends on the settings at ADDRESS 3011, option 3. By default, the
programmed time unit is in seconds.
Default setting: [000]
TABLE 1. Events Type
In case of setting of activation event and missing deactivation event (0), the PGM output restores in the way
described for the activation event!
ADDRESS:
3xx3 - Activation
00
The output is not used
Event No
ZONE Event - Description
Zone Open
Activated on "OR" function (if at least one of
the set area numbers is open the PGM is
01
activated)
ZONE OPEN
Deactivated on "AND" function (when all of
the set area numbers are closed the PGM
is restored)
02
Not used
Zone Bypassing
Activated on "OR" function (if at least one of
the set area numbers is bypassed the PGM
03
is activated, with no sense of the way of
ZONE
bypassing)
BYPASS
Deactivated on "AND" function (when all of
the set area numbers are not bypassed the
PGM is restored)
04-07
Not used
Zone Tamper
Activated on "OR" function (if at least one of
08
the set area numbers is with open tamper
ZONE
the PGM is activated)
Deactivated on "AND" function (when all of
TAMPER
the set area numbers are with closed
tamper the PGM is restored)
09-11
Not used
3017
317 + 01
5. OUTPUTS – 2. PGMs – 01. PGM – 7. DEACT TIMER
3019
319 + 01
5. OUTPUTS – 2. PGMs – 01. PGM – 8. DELAY
ADDRESS:
3xx4 – Set Parameter 1
PARAMETERS 1
Enter zone number "FROM"
-
Enter zone number "FROM"
-
Enter zone number "FROM"
-
50
ADDRESS:
3xx5 – Set Parameter 2
PARAMETERS 2
Enter zone number "TO"
"00" – not used, operates only
"FROM"
-
Enter zone number "TO"
"00" – not used, operates only
"FROM"
-
Enter zone number "TO"
"00" – not used, operates only
"FROM"
-