Appendix - Quick Guide Of The Engineer Programming Menus - Teletek electronics ECLIPSE 8 Installation Manual

Alarm control panel
Hide thumbs Also See for ECLIPSE 8:
Table of Contents

Advertisement

8. APPENDIX – Quick Guide of the Engineer Programming Menus
Text Menu
1. Maintenance
1. View Log
2. Walk Test
3. PGM Test
4. Comm. Test
5. Software Revision
2. Settings
01. Ambush Code
02. KBD Block
02. Chime
03. Trouble Sounds
04. Conf. Timer
05. AC Delay
06. Sound Tamper
07. Alarm Delay
08. Hardware reset
09. Part. Default
1. Settings
2. Codes
3. Inputs
4. Outputs
5. Partitions
6. Schedules
7. Communication
8. Devices
10. Reset Manager
11. System Name
12. Time
13. Date
14. Menu Style
15. Standard
3. Codes
1. Users
XX. User
1. Options
2. Areas
3. Name
4. Proxy Options
5. Time Slot
6. RC*(A) Function
7. RC(B) Function
2. Engineer
1. ENG1 Code
2. ENG2 Code
3. Code Length
4. Code Clone
4. Inputs
1. Wiring
2. AutoBypass
3. Instant (type zones)
4. Pulse Count
1. Pulses
2. Time Out
5. Zones
XX. Zone
1. Attach
2. Type
3. Areas
4. Options 1
Address Menu
Eclipse 8
0040
0020
0021
0023
0098
0010
[Disable/Enable]
0011
0012
[Disable/Enable]
0013
[Disable/Enable]
0014
0015
0016
[Disable/Enable]
0017
0030
[Disable/Enable]
0031
0031 [0]
Returns to default parameters of all general settings in the system.
0031 [1]
0031 [2]
Returns to default parameters and operation of Inputs and Zones.
0031 [3]
0031 [4]
0031 [5]
0031 [6]
Returns to default parameters and operation of all communication devices.
0031 [8]
Deletes all devices connected to the system bus, except the PCB of the panel.
0032
Perform a reset of the Manager code. Default: 0000 Confirm with 123456.
0050
Enter a unique name for the system. The menu is accessible via LCD keyboard.
0051
0052
0097
0096
1XXY
Programming of user rights and options; XX - user number; Y - option number.
1XXY
XX: 01-08
1.Disarm/2.Part. Arm/3.Zone Bypass/
1XX0
1XX1
1XX2
Enter a unique name for the User. The menu is accessible via LCD keyboard.
1XX3
1XX4
1XX5
1XX6
Change the Engineer code. Default: 7777. To change – press and hold "0".
0000
0001
1000
1001
2000
Set connection style 1-5. Default: 2.
2001
2002
2003
2004
2XXY
Programming of zone options; XX - zone number; Y - option number.
2XXY
XX: 01-08
2XX0
2XX1
2XX2
2.Bypass/3.Stay Arm/4.Sleep Arm/
2XX4
5.Force Arm/6.Double Knock
Eclipse 8/16/32/99 Series - Installation Manual
Eclipse 16
Review the memory log of the system.
Perform test for operation of all devices in the system.
Perform test of the operation of the PGM outputs in the system.
Perform test of the operation of the built-in digital communicator.
Review the software version of the panel.
[Disable/Enable]
-
-
-
[Disable/Enable]
-
Enter time in range 010-180 seconds. Default: 010
Enter time in range 000-254 minutes. Default: 030
[Disable/Enable]
-
-
[Disable/Enable]
Perform a reset for a selected menu. Confirm with code 123456.
Returns to default parameters and access codes of Users.
Returns to default parameters and operation of PGM outputs.
Returns to default parameters and operation of Areas.
-
-
Set the actual time.
Set the actual date.
Select the type of the programming menus:
4-digit Addresses [1], 3-digit operations [2], Text [3]
-
-
XX: 01-32
4.Programming
-
1-3
1. Disarm/2+3.Proxy card arming options
-
-
-
0.Unused/1.Sleep Arm/2.Stay Arm/3.Fire Alarm/
-
-
-
-
-
-
-
-
-
-
-
-
Number of activations 2-9. Default: 0 (Disabled).
-
Time for zones in pulse count: 000-255 sec. Default: 000 sec.
XX: 01-16
[DD] [TT] – DD: device number; TT: terminal number
-
00.Unused/01.Entry-Exit/02.Follow/03.Instant/04.Fire/05.Panic/
06.Tamper/07.Medical/08.Key-Switch/09.Auxiliary/10.Entry-Exit 2
-
1-3
37
Eclipse 32
[Disable/Enable]
[Disable/Enable]
-
[Disable/Enable]
[Disable/Enable]
[Disable/Enable]
[Disable/Enable]
Return to defaults for Time Slots.
Grade 2
XX: 01-64
1.Disarm/2.Part. Arm/3.Zone Bypass/
4.Programming/8.Manager
1-8
1-8
4.Medical Alarm/5.Police Alarm
Set a Maintenance code.
[4/6] – length of the access codes
Copying user options from one to more.
Set connection style 1-9. Default: 2.
Set number 1-9. Default: 6.
[Disable/Enable]
XX: 01-32
1-8
1.AutoBypass/2.Bypass/3.Stay Arm/
4.Sleep Arm/5.Force Arm/6.Double
Knock/7.Instant Exit/8.Fast (64ms)
Eclipse 99
[Disable/Enable]
[Disable/Enable]
-
[Disable/Enable]
[Disable/Enable]
[Disable/Enable]
[Disable/Enable]
Grade 2/Grade 3
XX: 01-99
1-16
1-16
[Disable/Enable]
XX: 01-99
1-16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eclipse 16Eclipse 32Eclipse 99

Table of Contents