Sound Signalization From The Keyboards; Supported Trouble Events In Eclipse Series - Teletek electronics ECLIPSE 16 Engineer Programming Manual

Alarm control panels
Table of Contents

Advertisement

Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
Summary for ECLIPSE Series Keyboards:
Keyboard
Display
LED 8
LED
LED 16
LED
LED 16A
LED
LED 32
LED
LCD 32
LCD
LCD 32S
LCD

2.2 Sound Signalization from the Keyboards

All Eclipse Series Keyboards have sound signalization for occurring of different system events. The sound signalization
has 4 volume levels adjustable at address 90 from the Manager programming menus.
Sound Signal
Description
Button
Single short beep indicating the pressing of a key.
Confirmation
Two long sound signals, indicating the system confirmation to executed operation.
Cancel
A single long beep, indicating system incorrectly executed operation.
operation
Entry time
Continuous beep, indicating intrusion into an entrance zone.
Short beeps, indicating the system is armed and the user is required to leave the entrance zone.
Exit time
Ten seconds before the exit time is over beep frequency increases.
Technical
Two short beeps at every 20 sec, indicating a technical trouble. To stop the signalization - press the
problem
TROUBLE button.
Short beeps with subsequently increasing period, indicating intrusion into a zone with an activated
Chime
chime option.
Three sound signals in sequence repeated every 5 seconds. That kind of signalization shows
Fire alarm
activated fire detector in the premises.

2.3. Supported Trouble Events in ECLIPSE Series

The possible system troubles are listed in the table below, together with the respective indication for LED and LCD
keyboards. The sound signalization for a system trouble can be disabled in menu 2. SETTINGS – 03. TRBL SOUNDS
(ADDRESS 0013 or OPERATION 013. By default, the sound signalization for all system troubles is enabled.
Note: The system troubles 7 and 8 are not supported for Eclipse 8/ 16 control panel.
LED
LCD
 1. AC Loss
 2. Battery Trouble
 3. Blown fuse
4. Tel. line TRBL/

Comm. Fail
 5. Tamper
 6. Sysbus err
 7. Fire line Error
 8. Siren Fault
Areas
Zones
Proxi
1
8
2
16
3
16
 (option)
8
32
 (option)
8
32
8
32
Description
The mains power supply is lost.
The accumulator battery is discharged or missing.
Blown out fuse.
Telephone line of the digital communicator is lost & communication with central Monitoring
station fails.
Open tamper in system.
System bus error. It could be short circuit in the line or lost device.
Fire Detector Loss or the fire line is broken.
Problem with connected siren; no siren connected to PGM5.
Address
8
Operation
Text menu