Teletek electronics ECLIPSE 16 Engineer Programming Manual page 72

Alarm control panels
Table of Contents

Advertisement

Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
ADDRESS
UDL
OPERATION
OPTIONS
TEXT MENU
Options for remote control
The following options are assigned:
1
2
Default setting: none
ADDRESS
RINGS
OPERATION
TEXT MENU
Setting the number of incoming rings.
The symbols 00 to 99 are used.
RINGS Up/ down loading is disabled if 0 is entered.
Default setting: 04
6904
694
8. COMMUNICATION – 1. DIGITAL COMM – 6. UDL – 5. OPTIONS
Enabling of "Call Back" option.
CALL BACK
CALL BACK Disable () – The option is disabled. In case of incoming
request for remote control, the panel will answer and start the procedure for
remote control.
CALL BACK Enable (1) – The option is enabled. In case of incoming request
for remote control from PC, the control panel will reject the answer and will
dial back the telephone number set at address 6900, and after that starts the
procedure for remote control.
Enabling of "Answering machine" option.
ANSWERING
ANSWERING MACHINE Disable () – The option is disabled. The
MACHINE
connection between the control panel and the telephone line is direct.
ANSWERING MACHINE Enable (2) – The option is enabled. Priority should
be given to any automatic answering devices (like FAX or telephone
answering machines), if such are connected to the telephone line.
The Answering Machine function should be enabled in such cases. During
initial income of a series of calls (rings), the ECLIPSE 32 temporizes the
maximum number of rings, set at Address 6905. The automatic answering
machine must be adjusted to a fewer number of rings. If within 4 minutes
there is another series of incoming calls the ECLIPSE 32 shall answer the
first one.
6905
695
8. COMMUNICATION – 1. DIGITAL COMM – 6. UDL – 6. RINGS