address 8xx2 – keyboard options).
Instant zone.
An alarm zone which is active only when the site is armed. The zone
operates instantaneously and activates the programmable ALARM and
SIREN type outputs, and the communicator.
INSTANT
When the system is disarmed, the activation of the zone is indicated
with active zone number for the time that the zone remains open.
An INSTANT type zone can be violated during Exit time running if at
ADDRESS 2002 (OPERATION 202) the "Enabled Instant" parameter is
enabled.
24 – hour fire type zone.
Allows connecting 12V fire detectors to the system. These should avail
of a normally closed relay output in inactive status. Any activation of the
FIRE
zone will trigger off SIREN type outputs, the programmable FIRE type
outputs and the digital communicator. The 24-hour fire type zones are
with the highest priority in the system and are indicated at first place.
24 – hour panic type zone.
Activating the zone will trigger off the PANIC type outputs, the SIREN
type outputs and the digital communicator. The PANIC type zones
operate in "Silent panic" mode when "3. Report only" option is set at
address 2хх5 – Setting of Attributes 2, where хх is the zone number. In
this case, the zone activation is not indicated on the keyboards (sound
PANIC
or LED indication), and only the digital communicator will send an alarm
message to the monitoring station.
After entering of valid user code the MEMORY button (LED) lights on
together with the LED/ number of the activated zone and area.
The indication of the memory can be deleted by entering a valid user
code, a manager code or during the next arming.
24 – hour tamper type zone.
Activating this zone type triggers off the SIREN output, the
programmable TAMPER type outputs and the station communicator.
When the system is disarmed and the TAMPER type output is
programmed as "DISABLE" at ADDRESS 0016 (OPERATION 016) –
Sound TAMPER, the activation of the zone will not be indicated on the
TAMPER
keyboards (sound or display indication), and only the digital
communicator will send an alarm message to the monitoring station. In
case the TAMPER type output is programmed as "ENABLED" at
address 0016, the activation of the zone will cause a sound signal from
the keyboards in DISARM mode.
24 – hour medical type zone.
Assigning this zone type will set the programmable MEDICAL and
SIREN type outputs active and will start the communicator.
The number of activated zone is displayed irrespective of the system
status.
The MEDICAL type zones operate in "Silent Panic" mode when the
attribute "3. Report only" is set at address 2хх5 – Setting of Additional
attributes, where "хх" is the zone number. In this case, the activation of
MEDICAL
the zone will not be indicated on the keyboards (sound or display
indication), and only the digital communicator will send an alarm
message to the monitoring station.
After entering of valid user code the MEMORY button (LED) lights on
together with the LED/ number of the activated zone and area.
The indication of the memory can be deleted by entering a valid user
code, a manager code or during the next arming.
Key-switch type, 24–hour alarm zone.
When this zone type is assigned, the respective panel input is used to
transmit the arming and disarming signal with the help of a key-switch.
The installer sets the type of the zone activation:
KEY-SWITCH
• With an impulse (PULSE attribute is set at ADDRESS 2016);
• Reaction of open or in normal operation mode zone (LATCH
attribute is set at ADDRESS 2016).