Intelligent interactive fire alarm control panel (25 pages)
Summary of Contents for Teletek electronics ECLIPSE 8
Page 1
USER OPERATION MANUAL ECLIPSE 8 ECLIPSE 16 ECLIPSE 32 (S.W. 1.9x) ALARM CONTROL PANELS Attention: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual Table of Contents: 1. GENERAL INFORMATION ................5 2. SUPPORTED KEYBOARDS ................6 2.1 LED Keyboards ................... 6 2.2 LCD Keyboards ................... 6 2.3 Buttons Functionality ................... 7 2.4 Indication ..................... 8 2.5 Sound Signalization ..................
Page 3
ECLIPSE 8/ 16/ 32 Series – User Operation Manual 5.5 Zones bypassing by Manager ..............24 5.6 Engineer Access ..................25 5.7 Assigning User attributes ................25 5.8 Associating Area numbers to User ............26 5.9 Entering of User names ................27 5.10 Associating Timeslots to User ..............
Page 4
ECLIPSE 8/ 16/ 32 Series – User Operation Manual GUARANTEE The guarantee terms are determined by the serial number (barcode) of the electronic device! During the guarantee period the manufacturer shall, at its sole discretion, replace or repair any defective product when it is returned to the factory.
The ECLIPSE family includes: ECLIPSE 8 for management of small sites up to 8 zones organized in 1 common area and for up to 8 users. ECLIPSE 16 for management of small to medium sites up to 16 zones organized in 3 independent areas and for up to 32 users.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual 2. SUPPORTED KEYBOARDS According your system configuration you may use one of the following keyboard models: Keyboard Display Areas Zones Card reader LED 8 LED 16 (option) LED 32 ...
ECLIPSE 8/ 16/ 32 Series – User Operation Manual 2.3 Buttons Functionality Button Function Description Confirmation of the entered data. For LED 8 and LED 16 keyboards: Use the button to review ENTER the memory log file, the system troubles and the bypassed zones –...
ECLIPSE 8/ 16/ 32 Series – User Operation Manual 2.4 Indication Button/LED Color Description The area is in FULL ARM mode. The area is in STAY ARM mode. The area is in SLEEP ARM mode. Permanently lit - there are bypassed zones in the system.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual 2.5 Sound Signalization All ECLIPSE Series Keyboards have sound signalization for occurring of different system events. The sound signalization has 4 volume levels adjustable at address 90 from the Manager programming menus.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual 2.6.2 Programming by Manager After manager code is entered, a confirmation beep is heard from the keypad. Entrance in programming mode by a manager is done by pushing the PRG ( ) button.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual 3. OPERATION INSTRUCTIONS 3.1 Arming With a Keyboard 3.1.1 Full Arming Mode Full Arm mode means that all zones in the armed areas are being protected. Full Arm can be initialized after entering a valid user code or with quick access without code, when this option is allowed in the menus for engineer programming.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual 3.1.4 Arming All Available Areas in the System The user can perform arming of all available for operation areas in system. To arm all areas use button “0”. According the way of arming – with or without entering a user code –...
ECLIPSE 8/ 16/ 32 Series – User Operation Manual LCD Keyboards The status of the used areas is viewed with pressing of ENTER button. Note that the “padlock” LED lights up in red only when all the used areas are armed. The “padlock” LED lights up in green if at least one of the used areas is disarmed.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual The exit from the open zones review mode is with pressing CANCEL button or automatically after 30 sec. 3.1.7 Changing the Arming Mode without Disarming This is an extra functionality for changing the current arming mode with other without disarming before that.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual The built-in card reader in LCD 32 Sensitive keyboard is situated in the right bottom corner on the front panel and it is marked with a “key” pictogram. 3.2.2 Arming via Stand-alone Proxy Reader...
ECLIPSE 8/ 16/ 32 Series – User Operation Manual When using LED keyboard, after the proxy card is recognized the numbers of the armed areas blink in red. The system will wait for the number of the areas to be entered.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual To review the system troubles press the TROUBLE button. In TROUBLE MODE viewing the TROUBLE button starts blinking. To exit TROUBLE MODE press CANCEL or wait 30 seconds for the system to leave this mode automatically.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual 4. USERS’ PROGRAMMING MENUS There are no default codes for ordinary users in the system. The Manager in the system can set new codes and allow certain users to have manager rights (for ECLIPSE 32).
2, because these keyboards do not have a MEMORY fast button. 4.3 Turning on the Chime signalization by User Attention: This menu is available for ECLIPSE 8 control panel only. The Chime signalization is a sound signal from the keyboards when opening an entry/ exit type zone.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual Address User Code Depending on the keyboard used, the visualization on screen is as follows: LCD 32 / LCD 32 Sensitive The Chime is enabled The Chime is disabled Press the digit buttons or arrow buttons to change alternatively the status of the Chime.
Page 21
ECLIPSE 8/ 16/ 32 Series – User Operation Manual Depending on the keyboard used, the visualization on screen is as follows: LCD 32 and LCD 32 Sensitive Zone is bypassed Zone is not bypassed Pushing the digit buttons or arrow buttons changes alternatively the state of the zone.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual 5. MANAGERS’ PROGRAMMING MENUS User 01 is always Chief Manager is the system. The default Chief Manager Code is 0000. Important Notes: The Chief Manager’s rights cannot be changed. One Manager cannot change other Manager codes.
See also the detailed description of item 4.2. 5.4 Turning on the Chime signalization by Manager Attention: This menu is available for ECLIPSE 8 control panel only. The Chime signalization is a sound signal from the keyboards when opening an entry/ exit type zone.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual 5.6 Engineer Access Disabling engineer access (access to the engineer programming menus) is done at address 05, after entering manager code: Address Manager code By default engineer access is ENABLED. Depending on the keyboard used, the visualization on screen is as follows:...
ECLIPSE 8/ 16/ 32 Series – User Operation Manual 1. Disarm The user code can disarm the system. 2. Stay and Sleep The user code can arm the system in STAY and SLEEP mode. 3. Zone Bypass The user code can bypass zones in the protected site.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual Address Manager code User Assigning area number numbers To every user code one or more areas can be assigned. By default for User code 01 (Manager) are assigned for operation all area numbers.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual Address Entering name Manager code User number The name can be up to 16 digits long – letters, numbers and intervals. The letters are chosen by pressing the respective digit number until reaching the desired letter.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual Time slot No 4 is associated No time slot is associated Timeslots are associated by pressing the respective digit number. The number of the chosen timeslot is lit permanently. LED 8 Enter at the address 09 and choose a user number - the LED for zone 1 is blinking on the display.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual Depending on the keyboard used, the visualization on screen is as follows: LCD 32 and LCD 32 Sensitive The card can disarm and arm in The card can disarm and arm in...
ECLIPSE 8/ 16/ 32 Series – User Operation Manual The card is recognized on the LCD display and its 10-digit unique code is shown on screen. If the registration of a card to a user code is successful, after pushing the ENTER button, a confirmation beep is heard.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual LED 16 and LED 32 Press and hold Card is deleted Associated card for 2-3 sec. LED 8 Enter at the address 11 and choose a user number - the LED for zone 1 is blinking on the display.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual LED 16 and LED 32 After entering address 13, digit 15 on the display blinks, while digit 16 is permanently lit – the system indicates that it is expecting entering of “Source” code. After entering the first digit of the code –...
ECLIPSE 8/ 16/ 32 Series – User Operation Manual 5.16 Setting the Date Setting the date is done at address 15, after entering manager code: Address Manager code Date [DD/ММ/YY] Depending on the keyboard used, the visualization on screen is as follows: LCD 32 and LCD 32 Sensitive With the help of the digit buttons, enter the date in the format [DD/ММ/YY] –...
ECLIPSE 8/ 16/ 32 Series – User Operation Manual Depending on the keyboard used, the visualization on screen is as follows: LCD 32 and LCD 32 Sensitive Address 16 Number from 000 to 255 With the help of the digit buttons enter the number of allowed incorrect codes.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual The remote disarming is By default all attributes are disabled enabled By pressing a digit button with corresponding number of attribute it is alternatively enabled or disabled. The attribute is enabled when the number is visualized on the screen. The disabled attributes are marked with “*”.
ECLIPSE 8/ 16/ 32 Series – User Operation Manual Increasing the volume Address Manager code The volume levels are shown on the keyboard displays as follows: LED 16/ 32 – Zone numbers are lit LCD – Number of symbols Volume level LED 8 –...
ECLIPSE 8/ 16/ 32 Series – User Operation Manual 5.22 Scroll speed of messages in LCD keyboards Attention: This address is available only in keyboards LCD32 and LCD32 Sensitive. At address 92 the scroll speed of system messages on the keyboard display is set. The available levels are from 1 to 7.
Page 39
ECLIPSE 8/ 16/ 32 Series – User Operation Manual Example: Suppose the event displayed on the keypad is represented by a LED combination of 3, 7 and 8. The table discloses the first LED 3 data entry. The next data entries disclose that of the first LED 7.
Page 40
ECLIPSE 8/ 16/ 32 Series – User Operation Manual Arming with user code - STAY Arming with user code - SLEEP Disarming with user code Remote arming - FULL Remote arming - STAY Remote arming - SLEEP ...
ECLIPSE 8/ 16/ 32 Series – User Operation Manual Fuse restore Telephone line loss Telephone line restore System power up System reset Time change Communication error for report to monitoring station Report to monitoring station restore ...
ECLIPSE 8/ 16/ 32 Series – User Operation Manual APPENDIX C – VD/ DTMF Operation Algorithm The user can realize remote management of the system if the system configuration is equipped with voice module. If during 40 seconds time interval there is no action – pressed button, the system will...
ECLIPSE 8/ 16/ 32 Series – User Operation Manual System Check List – Fill in from the Installer Zones Description...
Page 44
ECLIPSE 8/ 16/ 32 Series – User Operation Manual Zone Type Zone Type Zone Type PGMs Description PGM 1 PGM 3 PGM 5 PGM 2 PGM 4 System Timers Entry time, (sec.) Exit time, (sec.) The siren will be activated, (min.)