Teletek electronics ECLIPSE 16 Engineer Programming Manual page 77

Alarm control panels
Table of Contents

Advertisement

keyboards irrespective of their type.
 The option 1 can be programmed for the connected to the system bus proximity card readers.
 The options must be programmed for every device separately at the respective address.
 The options are not supported for devices type MAIN, ZEXP, PEXP and WEXP.
The following options are assigned:
1
2
3
4
* When the option is enabled, the keyboard will enter in confidential mode irrespective of the current
system status (Armed or Disarmed). The confidential mode is inactive when the system is in
programming mode (user, manager or engineer).
Default setting: 2. Zone Information Enable
ADDRESS
DEV 02
OPERATION
RESOURSES
TEXT MENU
On board resources of Device 02.
At this address, the engineer can check the on board resources (number of available zone inputs
and PGM outputs) for Device 02. This address is only for review. See also addres 8013 for
description of the indication from keyboards.
Default setting: according the type of the device and the used connection style
Enabling of sound signalization "Chime" for Device 02.
CHIME Disable () – The "Chime" is disabled.
CHIME Enable (1) – The "Chime" is enabled. The "Chime" sound signal is
activated in opening of entry-exit type zone.
CHIME
Note: This option is set only for the respective device (keyboard or card
reader) and can be enabled or disabled just for it at the address. The
"Chime" sound signalization must be enabled and for respective zone at
address 2xx5, option 6. Chime, where "xx" is the zone number. Also, the
device and the zone must be associated to at least one common area.
Hiding the zone information for Device 02, when the system is disarmed.
ZONE INFORMATION Display () – Every opening of a zone is displayed on
HIDING THE
the display with information for the zone number. For LED keyboards – the
ZONE
number of the zone is blinking.
INFORMATION
ZONE INFORMATION Hide (2) – The zone information is hidden. No
information is displayed on the displayed of Device 02.
Confidential mode entry for Device 02. The Confidential mode is a special
mode, where the system information of the main screen is locked and cannot
be viewed from the user.
CONFIDENTIAL MODE Disable () – The option is disabled. The main
screen shows information for the system status.
CONFIDENTIAL MODE Enable (3) – the option is enabled. When the
CONFIDENTIAL
programmed at address 0014 time is over the information for the current
MODE*
system status will be locked for viewing. The message "Confidential" is
displayed on the LCD keyboards, and there is no indication on the LED
keyboards.
Attention: The exit of the confidential mode is performed with pressing of a
random button or entering of valid code (user, manager or engineer),
according that 4. EXIT CONFIDENTIAL MODE option is disabled or enabled.
Confidential mode exit. The option defines the way of exit confidential mode.
EXIT CONFIDENTIAL MODE () – The option is disabled. The exit from
confidential mode is with pressing a random button.
EXIT
EXIT CONFIDENTIAL MODE (4) – The option is enabled. The exit from
CONFIDENTIAL
confidential mode is with entering of valid code.
MODE*
Attention: When the option 3. CONFIDENTIAL MODE is disabled the setting
of option 4. EXIT CONFIDENTIAL MODE does not matter.
8023
813 + 02
9. DEVICES – 02. DEVICE [NAME] – 4. RECOURSES
Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
77