Teletek electronics ECLIPSE 16 Engineer Programming Manual page 92

Alarm control panels
Table of Contents

Advertisement

Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
9. DEVICES
01. DEVICE [MAIN]
02. DEVICE [NAME]
31. DEVICE [NAME]
To the 1. MAINTENANCE Menu
* Note: The menus are accessible only proximity card readers.
1. ID
 AREA 1
2. AREAS
AREA 2
....
AREA 8
4. RESOURCES
1. ID
 AREA 1
2. AREAS
AREA 2
....
AREA 8
3. OPTIONS
CHIME
HIDE ZONE INFO
CONFIDENTIAL
CONF EXIT
4. RESOURCES
5. COMM QUALITY
6. ARM MODE A*
[s*******]
7. ARM MODE В*
[S*******]
92
NOTE!
Use buttons:
to DISABLE
to ENABLE
In the menus are set combinations of operation in the
areas – arming type and/ or disarming for every area.
Use the buttons to set the respective operation:
Button
Operation
[0]
No change of the Area state
[1]
Disarming
[2]
Full ARM
[3]
Stay ARM
[4]
Sleep ARM
Indication
[*]
[d]
[f]
[s]
[S]

Hide quick links: