Teletek electronics ECLIPSE 16 Engineer Programming Manual page 39

Alarm control panels
Table of Contents

Advertisement

9
AUXILIARY
Default setting:
Zone number
01
02
03
04
05
06
07
08
09-16
17-32
ADDRESS
Z1 AREAS
OPERATION
TEXT MENU
Association of Areas to Zone 01
According the system configuration the engineer associates one or several AREA numbers for
operation with ZONE 01. To select an AREA press the digit button corresponding to its number. The
next pressing of the same button will deselect the AREA.
To select all areas press button "0" – the button alternatively switches over all enabled / all disabled
state.
The zone will be inactive if there are no associated areas to it!
Default setting: AREA 1
ADDRESS
Z1 ATTR 1
OPERATION
TEXT MENU
Setting of Main Attributes for Zone 01
According the system configuration the engineer sets a range of main attributes for ZONE 01. More
than one attribute can be assign to the zone but it depends on its type. To select an attribute press
the digit button corresponding to its number. The next pressing of the same button will deselect the
attribute.
To select all attributes press button "0" – the button alternatively switches over all enabled / all
disabled state.
The Attributes from 1 to 7 can be assigned only for certain zone types – see the table below
for zone type compatibility! Some of the Attributes are not available in ECLIPSE 8/ 16 control
panel.
The following Attributes are available for setting at this address:
Arming is only possible in Full Arm mode. Arming will be anticipated
only when the system is ready - all zones are inactive.
The additional attributes for key-switch type zone is programmed at
address 2xx6 (OPERATION 216 + 01), where "xx" is the number of the
zone.
24-hour auxiliary type zone
When this zone type is assigned, respectively a number of AUX attribute
should be programmed at ADDRESS 2xx7, where xx is the number of
the zone (OPERATION 217 + xx).
ECLIPSE 8
ECLIPSE 16
2
3
3
3
5
6
1
1
2012
212 + 01
4. INPUTS – 5. ZONES – 01. ZONE – 3. AREAS
2014
214 + 01
4. INPUTS – 5. ZONES – 01. ZONE – 4. OPTIONS 1
Eclipse 8/ 16/ 32 Series - Engineer Programming Manual