Teletek electronics ECLIPSE 16 Engineer Programming Manual page 52

Alarm control panels
Table of Contents

Advertisement

Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
Panic Alarm in Area – Restore
Activate on "AND" function (when all area
numbers are panic alarm restored the PGM
30*
is activated)
Deactivated on "OR" function (if at least one
area is in panic alarm the PGM is restored)
31-35
Not used
Event No
CODE Events - Description
Valid User Code Enter
36
Activated on "OR" function (when a valid
VALID
CODE
user code is entered the PGM is activated)
ENTER
Deactivation on time - 5 sec.
Ambush Code Enter
Activated on "OR" function (when an
37
AMBUSH
ambush code is entered the PGM is
CODE
activated)
Deactivation on time - 5 sec.
Keyboard Block
Activated when 3 non valid user codes are
entered in sequence.
38
BLOCK KBD
Deactivation on time - 5 sec.
NOTE: The keyboard blocking must be
enabled at address 0011.
Proximity card using
Only for those cases when the proxy card
and the PGM output have common areas
and at least one of them is disarmed.
39
VALID
Activated on "OR" function (when a valid
PROXY
proximity card is placed in front of the card
reader the PGM is activated)
Deactivation on time - 5 sec.
40
Non valid proximity card using
INVALID
PROXY
Deactivation on time - 5 sec.
41-46
Not used
Event No
TROUBLE Event - Description
System Trouble
Activated on "OR" function (if at least one
47
system trouble is present the PGM is
SYSTEM
activated)
FAULT
Deactivated on "AND" function (when no
system troubles are present )
System Trouble - Restore
48*
Activated on "AND" function (when all
system troubles are restored )
All panic types are enabled
by default.
Enter the panic type:
1 – Silent panic
2 – Sound panic
3 – Silent medical
4 – Sound medical
5 – Fire
All panic types are enabled
by default.
-
PARAMETERS 1
Enter the number of user code
to start "FROM".
To set a single user code, enter 00 at the address for
PARAMETERS 2.
To set all possible user codes, enter 00 for both addresses
PARAMETERS 1 and PARAMETERS 2.
Enter the number of user code
to start "FROM".
To set a single user code, enter 00 at the address for
PARAMETERS 2.
To set all possible user codes, enter 00 for both addresses
PARAMETERS 1 and PARAMETERS 2.
-
Enter the number of proximity
card to start "FROM".
To set a single user code, enter 00 at the address for
PARAMETERS 2.
To set all possible user codes, enter 00 for both addresses
PARAMETERS 1 and PARAMETERS 2.
-
-
PARAMETERS 1
Enter the trouble type:
1 – AC power loss
2 – Battery loss
3 – Blown fuse
4 – Tel. line or communication
failure
5 – Tamper
6 – System bus error
7 – Fire line failure
8 – Siren fault
All system troubles are
enabled by default.
Enter the trouble type:
1 – AC power loss
2 – Battery loss
3 – Blown fuse
52
-
-
PARAMETERS 2
Enter the number of user code to
end "TO".
Enter the number of user code to
end "TO".
-
Enter the number of proximity
card to end "TO".
-
-
PARAMETERS 2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eclipse 8Eclipse 32

Table of Contents