Teletek electronics ECLIPSE 16 Engineer Programming Manual page 22

Alarm control panels
Table of Contents

Advertisement

Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
ADDRESS
CHIME
OPERATION
TEXT MENU
Chime Sound Signalization
At this address, you set the parameter as:
DISABLE
ENABLE
At this address, the engineer can enable or disable the "Chime" sound signalization activated for
opening of entry-exit type zones.
The parameter status can be changed with pressing of random button of the keyboard. The change
is confirmed with ENTER button.
Parameter by default: ENABLED
ADDRESS
TRBL
OPERATION
SOUNDS
TEXT MENU
The trouble sound indication (two short beeps in every 20 seconds) from the keyboard in Technical
Trouble mode is assigned at this address.
The sound signalization is available for the following troubles:
1. AC Loss
2. Battery Trouble
3. Blown fuse
4. Tel. line TRBL/
Comm. Fail
5. Tamper
6. Sysbus error
7. Fire line error
8. Sounder fault
It is possible after the initial startup of the system a trouble message for 8. SOUNDER FAULT to be
displayed on the screen of LCD keyboards (8 zone number lights on the LED display). That
indicates some problems with sounder connected to PGM5. If case the PGM5 is used as a standard
output, you have to terminate it with 1kOm resistor, or to program it as regular output – disable
option 1 at ADDRESS 3051.
The trouble sound signalization is enabling with pressing a button with the respective number from 1
to 8. Pressing the button with the same number again will disable the trouble indication for the
respective technical problem.
To disable/ enable all trouble sounds press button "0" – the button alternatively switches over all
enabled / all disabled state.
The set parameters are confirmed with pressing the ENTER button.
Parameter by default: All ENABLED
0012
012
2. SETTINGS – 02. CHIME
The "Chime" sound signalization is deactivated.
The "Chime" sound signalization is activated.
0013
013
2. SETTINGS – 03. TRBL SOUNDS
Main power supply loss.
Battery low charge or missing.
Fuse burnt out.
Telephone line trouble & no communication with central
monitoring station.
Open tamper in the system.
Error on the system bus, i.e. possible short circuit or lost device.
Fire Detector Loss; Broken fire line.
Possible problem or siren missing.
22