Ipv6 Nd Ns-Interval - Edge-Core ECS4810-12M Layer 2 Management Manual

Hide thumbs Also See for ECS4810-12M Layer 2:
Table of Contents

Advertisement

| IP Interface Commands
C
45
HAPTER
IPv6 Interface

ipv6 nd ns-interval

FF02::1:FF90:0/104
IPv6 link MTU is 1500 bytes
ND DAD is enabled, number of DAD attempts: 5.
ND retransmit interval is 1000 milliseconds
ND advertised retransmit interval is 0 milliseconds
ND reachable time is 30000 milliseconds
ND advertised reachable time is 0 milliseconds
Console#
R
C
ELATED
OMMANDS
ipv6 nd ns-interval (1190)
show ipv6 neighbors (1192)
This command configures the interval between transmitting IPv6 neighbor
solicitation messages on an interface. Use the no form to restore the
default value.
S
YNTAX
ipv6 nd ns-interval milliseconds
no ipv6 nd ns-interval
milliseconds - The interval between transmitting IPv6 neighbor
solicitation messages. (Range: 1000-3600000)
D
S
EFAULT
ETTING
1000 milliseconds is used for neighbor discovery operations
C
M
OMMAND
ODE
Interface Configuration (VLAN)
C
U
OMMAND
SAGE
This command specifies the interval between transmitting neighbor
solicitation messages when resolving an address, or when probing the
reachability of a neighbor. Therefore, avoid using very short intervals
for normal IPv6 operations.
E
XAMPLE
The following sets the interval between sending neighbor solicitation
messages to 30000 milliseconds:
Console(config)#interface vlan 1
Console(config)#pv6 nd ns-interval 30000
Console(config)#end
Console#show ipv6 interface
VLAN 1 is up
IPv6 is enabled.
Link-local address:
FE80::200:E8FF:FE90:0/64
Global unicast address(es):
2009:DB9:2229::79, subnet is 2009:DB9:2229:0::/64
Joined group address(es):
FF01::1/16
FF02::1/16
– 1190 –

Advertisement

Table of Contents
loading

Table of Contents