Mep Fault-Notify Lowest-Priority - Edge-Core ECS4810-12M Layer 2 Management Manual

Hide thumbs Also See for ECS4810-12M Layer 2:
Table of Contents

Advertisement

C
OMMAND
CFM Domain Configuration
C
OMMAND
A fault alarm is issued when the MEP fault notification generator state
machine detects that a time period configured by this command has
passed with one or more defects indicated, and fault alarms are enabled at
or above the priority level set by the
command.
E
XAMPLE
This example set the delay time before generating a fault alarm.
Console(config)#ethernet cfm domain index 1 name voip level 3
Console(config-ether-cfm)#mep fault-notify alarm-time 10
Console(config-ether-cfm)#
This command sets the lowest priority defect that is allowed to generate a
mep fault-notify
fault alarm. Use the no form to restore the default setting.
lowest-priority
S
YNTAX
D
EFAULT
Priority level 2
C
OMMAND
CFM Domain Configuration
C
OMMAND
M
ODE
U
SAGE
mep fault-notify lowest-priority priority
no fault-notify lowest-priority
priority – Lowest priority default allowed to generate a fault alarm.
(Range: 1-6)
S
ETTING
M
ODE
U
SAGE
A fault alarm can generate an SNMP notification. It is issued when the
MEP fault notification generator state machine detects that a configured
time period (see the
mep fault-notify alarm-time
with one or more defects indicated, and fault alarms are enabled at or
above the priority level set by this command. The state machine
transmits no further fault alarms until it is reset by the passage of a
configured time period (see the
without a defect indication. The normal procedure upon receiving a
fault alarm is to inspect the reporting MEP's managed objects using an
appropriate SNMP software tool, diagnose the fault, correct it, re-
examine the MEP's managed objects to see whether the MEP fault
notification generator state machine has been reset, and repeat those
steps until the fault is resolved.
Only the highest priority defect currently detected is reported in the
fault alarm.
– 1129 –
| CFM Commands
C
41
HAPTER

mep fault-notify lowest-priority

command) has passed
mep fault-notify reset-time
command)