Sflow Commands - D-Link xStack DGS-3400 Series Reference Manual

Xstack dgs-3400 series layer 2 managed gigabit ethernet switch
Hide thumbs Also See for xStack DGS-3400 Series:
Table of Contents

Advertisement

xStack
The sFlow commands in the Command Line Interface (CLI) are listed (along with the appropriate parameters) in the
following table.
Command
create sflow flow_sampler
config sflow flow_sampler
delete sflow flow_sampler
create sflow counter_poller
config sflow counter_poller
delete sflow counter_poller
create sflow analyzer_server
config sflow analyzer_server
delete sflow analyzer_server
enable sflow
disable sflow
show sflow
show sflow flow_sampler
show sflow counter_poller
show sflow analyzer_server
Each command is listed, in detail, in the following sections.
create sflow flow_sampler
Purpose
Syntax
Description
Parameters
®
DGS-3400 Series Layer 2 Gigabit Ethernet Managed Switch CLI Manual
Parameters
ports [<portlist> | all] analyzer_server_id < value 1-4> {rate <value 0-65535> |
tx_rate <value 0-65535> | maxheadersize <value 18-256>
ports [<portlist> | all] {rate <value 0-65535> | tx_rate <value 0-65535> |
maxheadersize < value 18-256 >}(1)
ports [<portlist> | all]
ports [<portlist> | all] analyzer_server_id < value 1-4> {interval [ disable | <sec
20-120>]}
ports [<portlist> | all] interval [disable | <sec 20-120>]
ports [<portlist> | all]
< value 1-4 > owner<name 16> {timeout [<sec 1-2000000> | infinite] |
collectoraddress [<ipaddr> | <ipv6addr>] | collectorport <udp_port_number 1-
65535> | maxdatagramsize < value m-n>}
< value 1-4 > {timeout [<sec 1-2000000 > | infinity] | collectoraddress [ <ipaddr>
| <ipv6addr>] | collectorport <udp_port_number 1-65535> | maxdatagramsize <
value 300-1400 >}(1)
< value 1-4 >
Used to create the sFlow flow_sampler.
create sflow flow_sampler ports [<portlist> | all] analyzer_server_id < value 1-4> {rate
<value 0-65535> | tx_rate <value 0-65535> | maxheadersize <value 18-256>
Used to create the sFlow flow_sampler. By configuring the sampling function for a port, a
sample packet received by this port will be encapsulated and forwarded to analyzer server at
the specified interval.
ports - Specifies the list of ports to be configured.
analyzer_server_id - Specifies the ID of a server analyzer where the packet will be
forwarded.
rate - The sampling rate for packet Rx sampling.
tx_rate - The sampling rate for packet Tx sampling.
maxheadersize - The maximum number of leading bytes in the packet which has been
sampled that will be encapsulated and forwarded to the server. If not specified, the default