16. Malfunction code
16.5.131 CE002: Message and method parameter failure
MFP board (MFPB)
Step
If it occurred after upgrading the firmware,
conduct the following setting.
[Service Mode] → [Sate Confirmation] →
1
[Memory/HDD Adj.] → [HDD Version Up]
See P.425
Turn OFF the main power switch and turn it
ON again, and conduct the following set-
ting.
2
[Service Mode] → [System 1] → [Initializa-
tion] → [Data Clear].
See P.390
3
Format hard disk.
4
Change hard disk.
5
Change MFPB.
16.5.132 CEEE1: MSC undefined malfunction occurring
MFP board (MFPB)
Step
Check the connectors on MFPB for proper
1
connection and correct as necessary.
2
Change MFPB
16.5.133 CEEE2: Scanner section undefined malfunction
Scanner assy
Step
Correct the connector connection between
1
CCDB and IPB if faulty.
2
Change IPB
3
Change CCDB