Konica Minolta bizhub C353 Service Manual page 498

Field service
Hide thumbs Also See for bizhub C353:
Table of Contents

Advertisement

Field Service Ver. 3.0 Jan. 2008
14.1.3
Scanner position adjustment
This adjustment must be made in the following case:
• The scanner drive cables have been rewound.
• Focus positioning of the scanner and mirrors unit must be completed.
[1]
[2]
4. Mount the original glass moving unit, and adjust the height of the original glass moving
unit.
See P.454
5. Whenever the scanner drive cables have been removed, be sure to carry out the [Feed
Direction Adjustment] procedure.
See P.355
6. Perform the following setting.
[Service Mode] → [ADF] → [Read Pos Adj]
See P.32 of the DF-611 service manual.
A00JF2C424DA
21.0 mm
[2]
[1]
A00JF2C425DA
14. Mechanical adjustment
1. Move the scanner assy [1] and the
mirror unit to the end of the right.
2. Slide the mirror unit until it hits the
end of the IR right frame.
3. Provide the length of 21.0 mm
between the end of the left indenta-
tion [1] on the scanner assy upper
surface and the end of the IR right
frame upper surface. When the
length is ensured, tighten the two
screws [2].
453

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub c253Bizhub c203

Table of Contents