3. Firmware upgrade
Error code
Control panel
• It failed to prohibit the job. (It failed to
lock the operation.)
→ It failed to lock the job because the
0x10000103
operation is already locked with
PSWC, etc.
• There is no space for F/W data to be
0x10000104
downloaded.
0x10000106
• Check sum error
File access error
• The file downloaded has an error.
• The header of the file which has been
read has an error.
0x10000107
• The size of the file to be downloaded is
too large.
• When it is identified to be the different
type of F/W.
• The area F/W is stored is destroyed,
0x10000108
and another ISW is necessary.
The temporary error when running the
subset
• When starting the Internet ISW in a
normal program, the rebooting will start
and the Internet ISW will be executed
0x20000000
with the subset program.
During the process by the subset pro-
gram, it has to be in the "Failed" status
unless the Internet ISW is successfully
conducted. This code is used tempo-
rarily to make it in error status.
30
Description
Field Service Ver. 3.0 Jan. 2008
Countermeasure
• Check if the following setting is set to
"Valid".
[Service Mode] → [Internet ISW] →
[Internet ISW setting]
• If the above process does not solve the
problem, inform the corresponding
error code to the KONICA MINOLTA.
• Check to see if the downloaded F/W is
of the correct type.
• Wait until ISW is automatically exe-
cuted on MFP side.