Konica Minolta bizhub C353 Service Manual page 279

Field service
Hide thumbs Also See for bizhub C353:
Table of Contents

Advertisement

8. Utility Mode
(2) Printer Adjustment
<Leading Edge Adjustment>
• It will not be displayed when the following setting shows that Management Device 1 is
mounted during the device power is OFF or no authentication is set.
[Service Mode] → [Billing Setting] → [Management Function Choice]
• This menu is unavailable when the key counter is not inserted while only the key counter
is set to Set by [Service Mode] → [Billing Setting] → [Management Function Choice].
Functions
• To vary the print start position in the sub scan direction for each of different paper
types in the manual bypass tray.
Use
• The PH unit has been replaced.
• The paper type has been changed.
• The image on the copy deviates in the sub scan direction.
• A faint image occurs on the leading edge of the image.
• Able to make an individual adjustment for each paper type of plain paper, thick 1,
thick 2, thick 3, thick 4, transparencies, and envelopes.
Adjustment
Specification
Width A
Adjustment
If width A is longer than the specifications, make the setting value smaller than the cur-
Instructions
rent one.
If width A is shorter than the specifications, make the setting value greater than the cur-
rent one.
Setting/
1. Place A3 paper on the manual bypass tray.
Procedure
2. Call the Administrator Settings to the screen.
3. Touch [System Settings] → [Expert Adjustment] → [Printer Adjustment] → [Leading
Edge Adjustment].
4. Select the [Normal].
5. Press the Start key to let the machine produce a test pattern.
6. Check the dimension of width A on the test pattern.
7. If width A falls outside the specified range, change the setting using the [+] / [-] key.
8. Press the Start key to let the machine produce a test pattern.
9. Check the dimension of width A on the test pattern.
10.If width A is outside the specified range, change the setting again and make a check
again.
11.If width A falls within the specified range, touch [OK].
12.Following the same procedure, adjust for thick 1 to 3, OHP, and envelope.
234
Field Service Ver. 3.0 Jan. 2008
Width A on the test pattern produced should
fall within the following range.
Specifications: 4.2 ± 0.5 mm
Setting range: -3.0 mm to +3.0 mm
A00JF3C504DA
(in 0.2 mm increments)