Suzuki GSF1250 Service Manual page 237

Hide thumbs Also See for GSF1250:
Table of Contents

Advertisement

• Apply SUZUKI BOND to the cam end caps of the
gasket as shown.
: Sealant 99000–31140 (SUZUKI Bond
1207B or equivalent)
• Apply engine oil to both sides of the gaskets.
CAUTION
!
Use the gaskets with new ones to prevent oil
leakage.
• Tighten the cylinder head cover bolts (4) to the
specified torque.
Tightening torque
Cylinder head cover bolt: 14 N·m (1.4 kgf-m, 10.0
lb-ft)
PAIR System
• Install the PAIR component parts. Refer to "PAIR
Reed Valve Removal and Installation in Section 1B
(Page 1B-6)".
I718H1140076-01
Ignition Coil / Plug Cap and Spark
• Install the ignition coil/plug caps. Refer to "Ignition Coil
/ Plug Cap and Spark Plug Removal and Installation in
Section 1H (Page 1H-4)".
Thermostat Connector
• Install the thermostat connector and pour engine
coolant. Refer to "Thermostat Connector / Thermostat
Removal and Installation in Section 1F (Page 1F-9)"
and "Cooling System Inspection in Section 0B
(Page 0B-12)".
I718H1140078-01
Engine Mechanical:
1D-35
I718H1140079-01
I718H1140080-01
I718H1140151-01