1A-65 Engine General Information and Diagnosis:
Step
2
4) Insert the needle pointed probes to the lead wire coupler.
5) Check the continuity between the Dg wire and ground. If
the sound is not heard from the tester, the circuit
condition is OK.
Special tool
(A): 09900–25008 (Multi-circuit tester set)
(B): 09900–25009 (Needle pointed probe set)
Tester knob indication
Continuity test (
(B)
6) Connect the IAT sensor coupler.
7) Turn the ignition switch ON.
8) Insert the needle pointed probes to the lead wire coupler.
9) Measure the output voltage between the Dg wire and
ground.
Special tool
(A): 09900–25008 (Multi-circuit tester set)
(B): 09900–25009 (Needle pointed probe set)
Tester knob indication
Voltage (
)
IAT sensor output voltage
2.4 V at 23 °C (68 °F)
((+) terminal: Dg – (–) terminal: Ground)
Are the continuity and voltage OK?
Action
)
I718H1110063-03
(A)
(B)
I718H1110238-03
Yes
Go to Step 3.
(A)
No
• Dg wire shorted to
the ground.
• If wire is OK, go to
Step 3.