Suzuki GSF1250 Service Manual page 122

Hide thumbs Also See for GSF1250:
Table of Contents

Advertisement

1A-53 Engine General Information and Diagnosis:
NOTE
• After repairing the trouble, clear the DTC using SDS tool. Refer to "Use of SDS Diagnosis Reset
Procedures (Page 1A-13)".
• IAP sensor (No.2) is incorporated in the TP sensor/IAT sensor.
C17 for IAP sensor No.2 (Use of mode select switch)
Step
1
1) Turn the ignition switch OFF.
2) Check the IAP sensor (No.2) coupler for loose or poor
contacts.
If OK, then measure the IAP sensor (No.2) input voltage.
3) Disconnect the IAP sensor (No.2) coupler.
4) Turn the ignition switch ON.
5) Insert the needle pointed probes to the lead wire coupler.
6) Measure the voltage at the R wire and ground.
If OK, then measure the voltage at the R wire and B/Br
wire.
Special tool
(A): 09900–25008 (Multi-circuit tester set)
(B): 09900–25009 (Needle pointed probe set)
Tester knob indication
Voltage (
)
IAP sensor (No.2) input voltage
4.5 – 5.5 V
((+) terminal: B – (–) terminal: Ground, (+) terminal: R
– (–) terminal: B/Br)
Is the voltage OK?
Action
I718H1110168-03
(A)
(B)
I718H1110180-03
Yes
Go to Step 4 (or P1750
for IAP sensor No.2
(Use of SDS)).
No
• Loose or poor
contacts on the ECM
coupler.
• Open or short circuit
in the R or B/Br wire.