Muffler & Exhaust Pipe Installation - Suzuki GW250 Service Manual

Table of Contents

Advertisement

MUFFLER & EXHAUST PIPE INSTALLATION
4 – 6 mm (0.16 – 0.24 in)
VIEW A
3 – 5 mm (0.12 – 0.20 in)
VIEW C
1 HO2 sensor
2 Muffler
3 Rear muffler cover
4 Connector
5 Exhaust pipe
*1 Apply muffler seal.
A
A
The chamfer side of connector face the muffler
*2
side.
*3 Contact the connector 4 to the stopper.
Install the connector 4 to the exhaust pipe 5
*4
and then install the muffler 2.
B
C
*1
C
B
*4
*2
SERVICING INFORMATION 10-27
0 – 2 mm (0 – 0.8 in)
FWD
*3
VIEW B
ITEM
N·m kgf-m lbf-ft
A
23
2.3
B
25
2.5
C
10
1.0
D
17
1.7
16.5
18.0
7.0
12.5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gw250l3

Table of Contents