4-4 FI SYSTEM DIAGNOSIS
• When taking measurements at electrical connectors using a
tester probe, be sure to insert the probe from the wire harness
side (rear) of the connector/coupler.
• When connecting meter probe from the terminal side of the
coupler (where connection from harness side not being possi-
ble), use extra care not to force and cause the male terminal
to bend or the female terminal to open.
Connect the probe as shown to avoid opening of female ter-
minal.
Never push in the probe where male terminal is supposed to
fit.
• Check the male connector for bend and female connector for
excessive opening. Also check the coupler for locking (loose-
ness), corrosion, dust, etc.
• Avoid applying grease or other similar material to connec-
tor/coupler terminals to prevent electric trouble.

FUSE

• When a fuse blows, always investigate the cause to correct it
and then replace the fuse.
• Do not use a fuse of a different capacity.
• Do not use wire or any other substitute for the fuse.

SWITCH

• Never apply grease material to switch contact points to pre-
vent damage.